My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_2011-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:44 AM
Creation date
6/23/2020 6:59:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2013
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0517272_15237 N THORNTON_2011-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sums ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer a Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ®Pressure ❑Vacuum ❑Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Incon Incon TS-STS Tester Equipment Resolution: +/-0.002" <br /> MEMEMSEEMEMESIMM <br /> Fill Sump# 87 Fill Sump# 87 Fill Sump# 87 Fill Sump# 87 <br /> Sum Diameter: 36" 36" 36" 36" <br /> Sum De the 60" 60" 60" 60" <br /> Height from Tank Top to Top of 15" 17" 15" 16" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 30" 30" 32" 31" <br /> Electrical Penetration: <br /> Condition of sump prior to Dry Dry Dry Dry <br /> testing: <br /> Portion of Sump Tested 34" 35" 36" 35" <br /> Sump Material: Fiberglass Fiber lass Fiber lass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 15 minutes 15 minutes 15 minutes 15 minutes <br /> starting test: <br /> Test Start Time: 9:16am 9:36am 9:16am 9:36am 10:11 am 10:28am 10:11 am 10:28am <br /> Initial Reading (RI): 4.7621" 4.7618" 4.3756" 4.3751" 5.5485" 5.5487" 4.0976" 4.0970" <br /> Test End Time: 9:31 am 9:51 am 9:31 am 9:51 am 10:26am 10:43am 10:26am 10:43am <br /> Final Reading(RF): 4.7617" 4.7615" 4.3752" 4.3751" 5.5482" 1 5.5488" 4.0972" 4.0959" <br /> Test Duration: 15 Minutes Each 30 15 Minutes Each 30 15 Minutes Each 30 15 Minutes Each 3 <br /> Chane in Reading(RF-RI): -0.0004 1 -0.0003 -0.0004 0.0000 -0.0003 0.0001 -0.0004 -0.0011 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" +/-0.002 +/-0.002" +/-0.002 +/-0.002" +/-0.002 <br /> Test Results ® Pass 0 Fail 19 Pass 0 Fail ® Pass 0 Fail 19 ]Pass D Fail <br /> Is there a sensor in the sump? ®Yes ❑No ®Yes ❑No ®Yes ❑No 91 Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is W Yes ❑No ❑NA ®Yes ❑No [INA ®Yes ❑No ❑NA ®Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? ®Yes ❑No ❑NA ®Yes; []No ❑NA ®Yes ❑No ❑NA 9 Yes ❑No ❑NA <br /> Was sensor properly replaced and ®Yes ❑No ❑NA 9 Yes ❑No ❑NA ®Yes ❑No ❑NA ®Yes ❑No ❑NA <br /> verified functional after testin ? <br /> Comments-(include information on repairs made prior to testing, and recommendedfollow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.