Laserfiche WebLink
San Joaquin County W <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, Califomia95205-6232 <br /> Telephone. (209) 468-3420 Fax. (209) 468-3433 Web.www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Narne- Facility Address- Date: <br /> NG J T, ,'%V N <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions o V o R Ei COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years o V o R Ej COS <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site o V o R o COS <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site o V o R o COS <br /> 205 CCR 2712(1) Operating permit not on site o V o R o COS <br /> 206 HSC 25294,25295 Failed to record or report unauthorized release in appropriate time frame o V i-i R Ei COS <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed w V w R Ei COS <br /> 208 CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months o V Ej R o COS <br /> 209 CCR 2715(o Designated operator employee training not performed or log not kept N V D R o COS <br /> 210 1 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD o V o R o COS <br /> 211 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept o V o R o COS <br /> 212 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept o V o R o COS <br /> UST System Observations <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills Ei V Ei R c.COS <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003) o V o R o COS <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003-Jun 2004) o V o R Ei COS <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004) Ei V c R o COS <br /> 305 HSC 25290.1 VPH monitoring of the interstitial spaces of the UST system is not maintained o V o R oCOS <br /> 306 CCR 2630(4) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity Ei V o R Ei COS <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained Ei V o R i:i COS <br /> 308 CCR 2636(f) Faited to maintain a continuous monitoring system that activates an audible and visual alarm o V o R Ei COS <br /> 309 CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC o V o R ci COS <br /> 310 CCR 2636(f)(1) Sensor in a turbine sump failed to activate an audible and visual alarm or stop the flow product Ej V o R oCOS <br /> 311 CCR 2636(%5) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs o V o R o COS <br /> 312 CCR 2636 Failed to property program or operate leak detection equipment Ei V o R o COS <br /> 313 CCR 2638(o Failed to affix a tag sticker on monitoring equipment certified,repaired,or replaced o V o R o COS <br /> 314 CCR 2631(a) Primary containment not fight(pre-Jul 2003) o V o R o COS <br /> 315 HSC 25290.2(c)(1) Primary containment not tight(Jul 2003-Jun2004) o V o R o COS <br /> 316 HSC 25290.1(c)(1) Primary containment not tight(after Jun 2004) Ej V o R o COS <br /> 317 HSC 25290.1,25290.2, Secondary containment not tight o V o R o COS <br /> 25291 <br /> 318 CCR 2636(a) Failed to have secondary containment o V o R Ei COS <br /> 319 HSC 25291(e) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) o V Ei R o COS <br /> 320 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion o V Ei R o COS <br /> 25290.2(c3) <br /> Page 2 of 5 <br />