Laserfiche WebLink
San Joaquin County MW <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, Califomia95205-6232 <br /> Telephone. (209) 468-3420 Fax: (209) 468-3433 Web.www.sjgov.o[g/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> � "I'�'4 1 � ' ;a, 7 2 Ni 6' <br /> j <br /> o <br /> F' YING, <br /> UST System Observations <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump o V o R o COS <br /> 322 CCR 2636(0(2) Line leak detector not installed o V o R o COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi o V c R o COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty o V o R o COS <br /> 325 j CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons w V m R o COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements Ei V Ei R Ei COS <br /> 327 CCR 2635(b)(2) Overfill prevention was overridden Ei V Ei R o COS <br /> 328 HSC 25283.5 Unburied below grade LIST failed to meet exemption status o V o R E3 COS <br /> 329 CCR 2717.1(g) Tampered with red tag Ei V o R E3 COS <br /> 330 CCR 2717.1(f) Deposited petroleum into a red tagged UST o V c R o COS <br /> 331 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms o V o R m COS <br /> 332 CCR 2631.1 LIST system not compatible with the substance stored o V o R o COS <br /> 333 HSC 25298(b) Failed to comply with temporary closure requirements o V o R Ei COS <br /> 334 HSC 25298(c) Failed to comply with permanent closure requirements Ei V o R o COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V o R o COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed Ei V Ei R D COS <br /> 403 CCR 2643(4) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V i-i R D COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V o R o COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation o V o R o COS <br /> 2030 See below Unlisted Operations/Maintenance violation Ei V Ei R Ei COS <br /> 2060 See below Unlisted Design/Construction violation o V Ei R E3 COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> r � '�nq Q-4 � ey <br /> doe's <br /> q� <br /> U':�" N J 'J <br /> An z,(',c-,u i' i '�J­­ q Soic-,, 111711,-_,,n wa," r'.,uA P <br /> wh,,,�t 1,11, L25 0':� isde!-Ohf"Yinn thF' Inc'n."hor' V <br /> ."sw'h <br /> ' H ,1� MUHW'Arinq VvH�' !-)e <br /> per'qtr�nrrle,­"'. h-ni.nediately lclq irdlm the Cali,:�r, ia Enviicnmoerita,'3 Reportint' <br /> -"hf, 5 'N'4"� f )'-j'­' Cl'� -,!a, <br /> 'J'P�' !J� M ", �_"':D P'HU,Mk_'� ���4 "D� <br /> and c' te F� n' <br /> 1"his is ;,�i violaflon. <br /> Page 3 of 5 <br />