My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2022 11:15:56 AM
Creation date
6/23/2020 6:59:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
288
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Comments —(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Sensor was reinstalled at lowest point and not tested. <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)1 <br />SWRCB, January 2002 <br />JUL 2 9 2015 <br />4. TANK ANNULAR TESTING <br />Y <br />Test Method Developed By: <br />❑ Tank Manufacturer ❑ Industry Standard ❑ Professional-4pgiaeer. W <br />❑ Other (Spec) <br />Test Method Used: <br />❑ Pressure <br />❑X Vacuum <br />❑ Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: 4" Dial Gauge <br />Equipment Resolution: .2 <br />UG0100001 <br />Is Tank Exempt From Testing?' <br />❑Yes ❑X No <br />❑Yes ❑No <br />❑ Yes F1 No <br />❑ Yes ❑ No <br />Tank Capacity: <br />1,000 <br />Tank Material: <br />Steel Clad <br />Tank Manufacturer: <br />Modern Welding <br />Product Stored: <br />Diesel <br />Wait time between applying <br />pressure/vacuum/water and <br />30 Min <br />starting test: <br />Test Start Time: <br />9:01 AM <br />Initial Reading (Rj): <br />-10 HG <br />Test End Time: <br />10:01 AM <br />Final Reading (RF): <br />-10 HG <br />Test Duration: <br />1 Hour <br />Change in Reading (RF -R j): <br />0 <br />Pass/Fail Threshold or Criteria: <br />0 <br />Test Result: <br />❑X Pass ❑Fail <br />❑ Pass ❑Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />❑X Yes []No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />❑Yes [g]No ❑NA <br />❑Yes ❑ No ❑ NA <br />❑Yes ❑No ❑ NA <br />❑Yes ❑ No ❑ NA <br />verified functional after testing? <br />Comments —(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Sensor was reinstalled at lowest point and not tested. <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.