FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
288
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 0 0 RECEIVED <br />SWRCB, January 2002 OCT 2 0 2016 <br />6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard N ACL HEA L <br />❑ Other (Spec) DEFPARTMEN <br />H <br />Test Method Used: ❑ Pressure ❑ Vacuum ❑X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Incon TS -STS <br />Equipment Resolution: .0006 <br />Piping 000100001 <br />Pipe Tran 0001 0001 <br />Sump Diameter: <br />48" <br />28" x 28" <br />Sump Depth: <br />60" <br />36" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />24" <br />14" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />18" <br />27" <br />Condition of sump prior to testing: <br />Good <br />Good <br />Portion of Sump Tested' <br />2" above high pen <br />2" above high pen <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?` <br />❑Yes ❑No XNA <br />OYes ❑No EINA <br />❑Yes ❑No ❑NA <br />❑Yes [--]No DNA <br />Turbine shutdown response time <br />NA <br />NA <br />Is system programmed for fail-safe <br />shutdown?* <br />❑Yes ❑No ❑X NA <br />❑Yes ❑No ®NA <br />❑Yes ❑No ❑NA <br />❑Yes ❑No ❑NA <br />Was fail-safe verified to be <br />operational? <br />❑Yes ❑No ®NA <br />❑Yes ❑No ®NA <br />❑Yes ❑No [--INA❑Yes <br />❑No ❑NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />15 min <br />15 min <br />Test Start Time: <br />10:00am 10:16am <br />10:00am 10:16am <br />Initial Reading (Ri): <br />3.2157 3.2152 <br />3.3356 3.3357 <br />Test End Time.. <br />10:15am 10:31 am <br />10:15am 10:31 am <br />Final Reading (RF): <br />3.2152 3.2150 <br />3.3357 3.3357 <br />Test Duration: <br />15 min 15 min <br />15 min 15 min <br />Change in Reading (RF -R,): <br />.0005 .0002 <br />.0001 =0 <br />Pass/Fail Threshold or Criteria: <br />.002 .002 <br />.002 1.002 <br />Test Result: <br />❑X Pass ❑ Fail <br />0 Pass ❑ Fail <br />❑Pass ❑Fail <br />❑ Pass ❑Fail <br />Was sensor removed for testing? <br />[E]Yes ❑No DNA <br />❑X Yes ❑No ❑NA <br />❑Yes ❑No DNA <br />❑Yes ❑No ❑NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />❑Yes ❑X No ❑NA <br />❑Yes [Z]No❑NA <br />❑Yes ❑No ❑NA <br />❑Yes ❑No ❑NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Sensors were reinstalled to the lowest point, but not tested <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to as of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.