Laserfiche WebLink
E <br />I—V &I V Fil M <br />Pd e of <br />0. qu I I "JLUx%_"JLk7A N-- - ---- <br />Test Method Developed By: F] UDC Manufacturer ❑ Industry Standard Professional gineer <br />❑ Other (Specify) <br />Method Used: E] Pressure Vacuum ®Hydrostatic <br />[] Other (Specify) <br />Test Equipment Used: Caldwell Level Indicator Equipment Resolution: .002 <br />UDC #11-12 <br />UDC #UC <br />UDC #9-10 <br />UDC Manufacturer: <br />o <br />o <br />UDC Material: <br />fiber lass <br />fiberglass <br />UDC Depth: <br />30 <br />30 <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />12 <br />12 <br />— <br />a )nirz <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />testing: <br />14 <br />clean <br />14 <br />clean <br />r L It h rimimai Ilr <br />Wr­1 jr—nmr—Rap'l <br />Portion of UDC Testedr-- <br />2" above product <br />2" above product <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />OYesn No F1 NA <br />MYeso No F1 NA <br />FjYesF1 No El NA E]YI sE] No C] NA <br />31 <br />Turbine shutdown response time <br />No El NA <br />®Yes N <br />[]— <br />IZYesE] No EINA <br />Yes No El NA HY§sU No F-1 NA <br />Is system programmed for fail- <br />safe shutdown?* <br />CgYesFl No El NA <br />[DYes[:] No n NA <br />E]YesO No n NA ❑ s[:] No NA <br />Was fail-safe verified to be <br />operationalf <br />yes <br />yes <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />15miins <br />15mins <br />Test Start Time: <br />30mins <br />30mins <br />Initial Reading (Rt): <br />first circle <br />first circle <br />TestEnd Time: <br />Omins <br />Omins <br />Final Reading (RF): <br />no change <br />no change <br />Test Duration: <br />30mins <br />30mins <br />Change in Reading (RF -RD: <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/60mins <br />.005/60mins <br />Test Result: <br />0 Pass EJ ] ail <br />0 Pass El Fail <br />E] Pass M_F_�i_ n >am [:1 Fail <br />Was sensor removed for testing? <br />NYesEl No EINA <br />®Yes El No El NA <br />E]YesE]�s[_] No 0 NA <br />Was sensor property replaced and <br />verified functional after test <br />[Dyesn No DNA <br />Eyes[:] No n NA <br />nYesn No n NA f0j SM No n NA <br />Comments — (include information on <br />to testing, and recommended <br />If the entire depth of the UDC is not tested, specify how much was tested. <br />asterisk (*) is "NO" or "NA", the entire UDC must ba4ested. <br />If the answer to my of the questions ipdicated with an <br />