Laserfiche WebLink
E <br />E <br />Page — of <br />7. UNDER -DISPENSER CONTAINMENT (UDQ TESTING <br />Test Method Developed By: <br />❑UDC Manufacturer F] Industry Standard M Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: <br />El Pressure <br />E] Other (Specify) <br />0 Vacuum <br />®Hydrostatic <br />Test Equipment Used: Caldwell Level Indicator <br />UDC #1-2UDC <br />Equipment Resolution: .002_ <br />#3-4 UDC #5 -6 UDC #7-8 <br />UDC Manufacturer: <br />opw <br />opw <br />opw <br />opw <br />UDC Material. <br />fiberglass <br />fiber lass <br />fiberglass <br />fiber lass <br />UDC Depth: <br />30 <br />30 <br />30 <br />30 <br />Height from UDC Bottom to Top <br />of Highest Piin Penetration: <br />12 <br />12 <br />12 <br />12 <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />14 <br />14 <br />14 <br />14 <br />Condition of UDC prior to <br />testing: <br />clean <br />clean <br />clean <br />clean <br />Portion of UDC Tested <br />2" above product <br />2" above product <br />2" above product <br />2" above product <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />®Yes[] No 0 NA <br />RYesEl No F-1 NA <br />-No­[jN_A <br />SYesEl No n NA <br />ZYesE] No [_1 NA <br />Turbine shutdown response time <br />ZYes No NA <br />Yes E] <br />OYes [] No [] NA <br />[DYes[:] No [:] NA <br />Is system programmed for fail- <br />safe shutdown?* <br />ZYesE1 No El NA <br />®Yes[] No [:] NA <br />ZYesO No 0 NA <br />ZYes[:1 No F] NA <br />Was fail-safe verified to be <br />operational?* <br />yes <br />yes <br />yes <br />yes <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />15mins <br />15mins <br />15mins <br />15mins <br />Test Start Time: <br />30mins <br />30mins <br />30mins <br />30mins <br />Initial Readin (RI): <br />first circle <br />first circle <br />first circle <br />first circle <br />Test End Time: <br />0imns <br />Omins <br />Omins <br />Omins; <br />Final Reading (RF): <br />no change <br />no change <br />no change <br />no change <br />Test Duration: <br />30mins <br />30mins <br />30mins <br />30mins <br />Change in Reading (RF -RI): <br />0 <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30mins <br />.005/30mins <br />.005/30mins <br />.005/60mins <br />Test Result: <br />N Pass EJ Fail <br />Z Pass [I —FailN <br />Pass El Fail <br />ED Pass El Fail <br />Was sensor removed for testing?ZYesLr_1 <br />jNo[-]RA- <br />Yes <br />ED Yes No El NA <br />Yes RO NA <br />Q <br />Was sensor properly replaced and <br />verified functional after testing? I <br />ZYesE] No El NA <br />ZYesEJ No El NA <br />I <br />®Yes® No 0 NA <br />OYesEl No n NA <br />COMMentS - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to uqX of the questions indicated with an <br />asterisk (*) is "Ng' or "NK', the entire UDC must be testa <br />