My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2007-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 2:00:07 PM
Creation date
6/23/2020 6:59:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2015
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2007-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
438
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.smgov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Shell 1-5 Facility Insp <br />717 West Eighth Street, Stockton Daeection <br />Name: Address: Mar 5, 2014 <br /># I C1 I C2 I M I Code Section <br />702 <br />703 <br />999 <br />CCR: <br />CCR: <br />M <br />Other: <br />Biennial tightness test of gravity piping not <br />Triennial line test for conventional suction <br />a Vio 4 <br />See attached "Continuation — Officialylnsp( <br />(:Ocie; ui-K = (:Ode of federal Keguiations <br />= Class 2 violation; M = Minor violation <br />med (pre -January 1, 1984) <br />not performed (pre -January 1, 1984) <br />Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />UST Inspection: Routine & Annual Monitoring System Certification Minor violations: 306, 311,113,206 <br />306. Diesel fuel was found at the Diesel STP sump. Per technician, he removed approximately 2 cups of <br />fuel with absorbent pads. Technician used a clean white absorbent pad to wipe along the opening of <br />secondary fiberglass piping, primary fiberglass piping, flex piping, turbine and ATG risers, sump wall, <br />manway & bolts and found no areas of possible seepage. All primary containment must be product tight. <br />Correct by monitoring the diesel STP sump for areas of possible seepage on a regular basis. Have a <br />properly licensed, trained, and certified contractor replace or repair the failed piping under permit and <br />inspection of the EHD. <br />311. The premium unleaded mechanical line leak detector failed to detect a leak when tested. All line <br />leak detectors shall be capable of detecting a 3 -gallon per hour leak at 10 psi. The service technician <br />adjusted the leak detector once, retested it, and it passed. <br />113. A new designated operator Douglas L Nunn had started the monthly inspection reports in July 2013 <br />to present and notification was not provided to the EHD within 30 days of the change. Any changes <br />shall be reported to the EHD with 30 days. Immediately, submit notification to the EHD identifying all the <br />designated operators for this facility. Alternatively, log into CERS, upload the required information, and <br />submit for review by the EHD. <br />- Corrected on site. Copy of the Owner Statement of DO was found with inspector's name & fax # but no <br />copy was received by EHD. <br />206. Failed to include hiring date of employees trained by DO. DO training records were missing <br />employee's hiring date. List shall include dates of training and also hiring dates for all facility's <br />employees hired on or after July 1, 2005. <br />- Corrected on site. Owner documented the hire dates on training record. <br />Submit to SJC EHD within 30 days (04/05/14): <br />1. one copy of the completed "Return to Compliance Certification" form <br />2. a written statement how the to ensure the diesel UST is primary tight <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received By: �Q <br />EHD 23-02 IW04/19/12v Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.