Laserfiche WebLink
California Water Service Company 1602 E. Lafayette St., Stockton SR0063739 <br /> 5. Inert USTs with 30 pounds of dry ice per 1,000 gallon volume after triple rinsing. Be <br /> aware, additional testing/monitoring to ensure tanks remain inerted may be required by <br /> the Stockton Fire Department. <br /> 6. A copy of the submitted "Health and Safety Plan" must be on the jobsite for review. <br /> 7. See 'Sampling Protocol for Routine Tank Removals' and `Verification Analysis' on page <br /> 6 and 7 of the permit application for required analytical tests and number of samples to <br /> be taken and witnessed by EHD. <br /> 8. A copy of the Fire Department permit must be submitted at the time of removal. <br /> 9. In addition, the following information must be submitted within 30 days after the UST <br /> removal date: <br /> a. Analytical results: only results that come directly from a third party California certified <br /> laboratory with affixed chain of custody will be accepted by EHD <br /> b. UST Tracking Record Sheet and/or Tank Hazardous Waste Manifest <br /> c. Tank Closure Certification Form (DTSC Form 1249) <br /> d. Hazardous Waste Manifest for rinsate and residual product <br /> e. Backfill Excavation Certificate <br /> 10. Permit expires 180 days from the date of approval. If an extension to the expiration date <br /> is required, a written request must be submitted to this office prior to the expiration date. <br /> If you have any further questions, please contact me at (209) 468-3440. <br /> Thank you, <br /> Stacy Rive , EHS <br /> Senior Registered Environmental Health Specialist <br /> Cc: Chow Engineering <br /> 770 Pardee Lane, Suite 100 <br /> Oakland, CA 94621 <br /> 2 <br />