Laserfiche WebLink
A ` ,111'11J D A � � I N Environmental Health Department <br /> UU ;'� IY <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHASE CHEVROLET 6441 HOLMAN RD, STOCKTON September 13, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 512 CCR 66265.192(h) Failure to obtain an assessment or reassessment of a hazardous waste tank system. <br /> OBSERVATION: The facility did not have a current tank assessment on file for the red 1500 gallon used oil <br /> stationary tank and white 240 gallon used antifreeze stationary tank both located in the lube pit.Tank Assessments <br /> are required to be done every 5 years.The tank assessment for the 240 gallon used antifreeze tank and the 1500 <br /> gallon used oil tank was done on December 12, 2013. <br /> REGULATION GUIDANCE: The owner or operator of a hazardous waste tank shall obtain a written assessment <br /> reviewed and certified by an independent, qualified, professional engineer, registered in California attesting that the <br /> system has sufficient structural integrity, is acceptable for the transferring, storing, and treating of hazardous waste, <br /> and that the tanks and containment system are suitably designed. <br /> The hazardous waste tank assessment shall include all of the following information: <br /> 1.tank configuration (i.e., horizontal, vertical), material of construction, and gross capacity(in gallons); <br /> 2. design standard(s), if available, according to which the tank and ancillary equipment were or will be <br /> constructed and all of the following information: <br /> A. material of construction; <br /> B. material thickness and the method used to determine the thickness; <br /> C. description of tank system piping (material, diameter); <br /> D. description of any internal and external pumps; and <br /> E. sketch or drawing of tank including dimensions. <br /> 3. documented age of the tank system (if tank was previously used), if available, (otherwise, an estimate of the <br /> age); <br /> 4. description and evaluation of any leak detection equipment; <br /> 5. description and evaluation of any corrosion protection equipment, devices, or material; <br /> 6. description and evaluation of any spill prevention or overfill equipment; <br /> 7. description and evaluation of secondary containment for the tank system including applicable secondary <br /> containment for ancillary equipment as required in subsection 66265.193(f); <br /> 8. hazardous characteristics of the wastes that have been or will be handled. <br /> CORRECTIVE ACTION: Immediately have a tank assessment prepared for the 1500 gallon used oil stationary tank <br /> and 240 gallon used antifreeze stationary tank per Title 22 Section 66265.192. Submit a schedule showing when <br /> this will be accomplished to the EHD. <br /> This is a repeat violation, Class II. <br /> FA0010424 PR0514322 SCO01 09/13/2019 <br /> EHD 22-02 Rev.8/22/2019 Page 9 of 10 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />