A N J O A Q U IN <br /> Environmental Health Department <br /> COUNTY— <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHASE CHEVROLET 6441 HOLMAN RD, STOCKTON September 13, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 503 CCR 66265.192(k) Hazardous waste tank assessment is incomplete. <br /> OBSERVATION: The hazardous waste tank assessment for the 120 gallon used antifreeze stationary tank and the <br /> 294 gallon used oil stationary tank is incomplete.The report prepared and signed by the professional engineer on <br /> 8-24-15, certifies each tank as complying with subsection CCR 66265.192 (k). The tank assessment did not contain <br /> the full required Title 22 Section CCR 66265.192. <br /> REGULATION GUIDANCE: The hazardous waste tank assessment shall include all of the following information: <br /> 1.tank configuration (i.e., horizontal, vertical), material of construction, and gross capacity(in gallons); <br /> 2. design standard(s), if available, according to which the tank and ancillary equipment were or will be <br /> constructed and all of the following information: <br /> A. material of construction; <br /> B. material thickness and the method used to determine the thickness; <br /> C. description of tank system piping (material, diameter); <br /> D. description of any internal and external pumps; and <br /> E. sketch or drawing of tank including dimensions. <br /> 3. documented age of the tank system (if tank was previously used), if available, (otherwise, an estimate of the <br /> age); <br /> 4. description and evaluation of any leak detection equipment; <br /> 5. description and evaluation of any corrosion protection equipment, devices, or material; <br /> 6. description and evaluation of any spill prevention or overfill equipment; <br /> 7. description and evaluation of secondary containment for the tank system including applicable secondary <br /> containment for ancillary equipment as required in subsection 66265.193(f); <br /> 8. hazardous characteristics of the wastes that have been or will be handled. <br /> CORRECTIVE ACTION: Immediately amend the tank system assessment to include all required information as <br /> required in Title 22 Section CCR 66265.192 and submit a copy of the amendments to the EHD. <br /> This is a Class II violation. <br /> FA0010424 PR0514322 SCO01 09/13/2019 <br /> EHD 22-02 Rev.8/22/2019 Page 8 of 10 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />