COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOLMAN
>
6441
>
2200 - Hazardous Waste Program
>
PR0514322
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/25/2020 4:45:20 PM
Creation date
6/25/2020 10:49:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0514322
PE
2229
FACILITY_ID
FA0010424
FACILITY_NAME
CHASE CHEVROLET
STREET_NUMBER
6441
STREET_NAME
HOLMAN
STREET_TYPE
RD
City
STOCKTON
Zip
95212
CURRENT_STATUS
01
SITE_LOCATION
6441 HOLMAN RD
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Spill Prevention Compliance Corporation <br /> F.O. Box 1289........Waterford, CA 95386 Telephone: (209)969-0851 <br /> Emai I:..syc c orAhotmai l.com <br /> Website: www.socolan.com <br /> Certified Assessment Form (PE) for AST Systems <br /> Assessor: Spill Prevention Compliance Corporation Onsite Assessor:Todd McWhorter <br /> P.O. Box 1289 Telephone: „12091969-0851 <br /> Waterford,CA 95386 email: ssaccorp(u-hotmail.com <br /> Client: Chase Chevrolet Contact : Alex Robinson Service Manager <br /> Address: 6441 Holman Rd. Phone No.: 209475-6640 <br /> City/State/Zip; Stockton, CA 95212 Date of Test: 10-9-19 <br /> Assessment Data- Waste Oil AST-a <br /> L AST Configuration &age of AST Vertical AST Single wall steellapprox 25 yrs old{estimated) <br /> ]a. Useful Life Remaining of AST AST has approximately 20 years of remaining life (Subsection kl410) <br /> 2. AST Primary vessel construction(describe) 294 gals/Waste Oi1/UL# Not Accessible/UL142-Container/ <br /> Made to UL 142 construction standard-at least.093 in.steel thickness per UL Std for Safety for Steel <br /> Aboveground Tanks for Flammable and Combustible Liquids,suitable for containing waste oil._ <br /> 3. AST piping(describe)_lin. hydraulic hose to 1 in. elevated galvanized pipe to 1 inch copper pipe from (2) <br /> Graco Husky 1040 pneumatic pumps to 1 in.hydraulic hose to 2 in opening w/fitting,from pump for supply <br /> to top of AST.There is an inline check valve between quick connect hose pick-up& pump. Piping is <br /> adequately secured, supported& protected against physical damage and excessive stress due to settlement, <br /> vibration,expansion or contraction, & was tested,found to be in good condition & not leaking. <br /> 4. Internal/External pump description_external wall mounted in(2)steel cabinets-(2)Graco Husky 1040 <br /> pneumatic pumps w/2 solenoid 12volt-10-200psi-w/continuous.electronic monitoring & BJ Enterprises 007 SV <br /> pneumatic auto shut down-External pump.which pumps from waste oil caddies from service area Ancillary_ <br /> equipment is secured to wall,&supported and protected against physical damage and excessive stress due to <br /> settlement,vibration,expansion or contraction (see pie) <br /> 5. AST drawing(provided/drawn: source) (see attached <br /> 6. Design Standard(ASME, UL,etc.) UL 142-Single Wall Steel/Mfr: Ace Tanks <br /> 7. AST foundation(describe) concrete sub-floor,AT sits within a steel berm. Base of AST under UL 142 <br /> adequate to withstand the load of a full tank-Tank is anchored to wall. _,•___ <br /> 8. AST anchoring(seismic zone/floatation risk)AST is anchored,with a steel earthquake strap around the tank <br /> with 1/2 in.anchor bolts anchored into the concrete wall. with the steel strap being set at approximately 1-2 <br /> inches above% of the hei ht of the tank.. Stockton is a(groundshakinW potential liquefaction)seismic re ion <br /> These anchors are intended to secure the tank during a seismic event.There are two o scenarios which would <br /> create loads upon them. The first scenario is an em tank. With an emntv tank.the ex ansion anchors <br /> resist the overturnine moment throueh their tensile(pull-out)capacity—Since the anchors are installed at the <br /> perimeter of the tank,the distance between anchors(in either direction)provides a sufficient_lever arm for the <br /> concrete anchors to not exceed their allowable pull-out capacity. The second load case is with a partially full <br /> or full tank. In this scenario,because the liquid fills the bottom of the tank and increases its weight,the <br /> eoverning load case becomes the shear capacity of the concrete expansion anchors In the shear loading,all <br /> anchors resist the loads and their allowable capacity is not exceeded. This load case is conservative in its <br /> analysis since it neelects the friction force created by the weight of the partially full or full tank. This tank's <br /> rear is set in a corner, against the concrete walls,which further acts as a barrier to movement in the event of <br /> an earthquake.AST is situated in secured lubricants room,at the Northern side of Service area. The tanks <br /> are unlikely to move outside the room in a seismic event or a flooding event <br />
The URL can be used to link to this page
Your browser does not support the video tag.