Laserfiche WebLink
structure at the wall which further acts as a barrier to movement in the event of an earthquake.AST is <br /> situated in secured lubricants room at the basement SouthWest side of Express Lube Service area. The <br /> Otanks are unlikely to move outside the room in a seismic event or a flooding event <br /> 9. AST will withstand frost-heave XX Yes No AST is located in a covered secured lubricants enclosure <br /> not subject to weather conditions <br /> 10.AST previously relocated? Yes XX No <br /> 11.AST Corrosion Protection AST is located in secured covered lubricants room away from weather. Poly <br /> tank system not subiect to continuous UV extwsure-Poly tank not subiect to corrosion <br /> 12.AST Spill Prevention Equipment Filling system uses a mobile"transfer hump"for coolant replacement in <br /> vehicles and uses that same 12ump to pump product from top floor thru secured funnel into product supiply <br /> line and tank. Filling is pumped and also gravity fed into tank from upper level.Product supply line has <br /> manual ball valves as shut down devices. Entire basement area is secondary containment. Tank has integral <br /> secondary containment. ._ <br /> 13. Overfill Protection: This tank has continuous electronic monitoring with a BJ Enterprises Sentry Alarm_ <br /> which actuates at 85% fill level with a siren which sounds at 103 dB which is ade uste to notify operating <br /> personnel that hiah vroduct levels have been reached. Additionally,daily visual inspections would be <br /> adequate for overfill protection. A Daily inspection Log is attached to this report. This tank is emptied on a <br /> regular schedule,which precludes overfills as it is regularly emptied when far below hi levels. _ <br /> 14.Toxic Considerations: Antifreeze is toxic to humans and animals.Waste antifreeze contains heavy metals <br /> such as lead,cadmium,and chromium in high enough levels to potentially make it adulated hazardous <br /> waste,so most states strictly regulate antifreeze disposal.Antifreeze generators and state and local programs <br /> should not dump spent antifreeze on land or discharge it into a sanitary sewer,storm drain,ditch,dry well,or <br /> septic system; dumping antifreeze can cause serious water quality problems and might harm people,pets,or <br /> wildlife. <br /> 15. AST secondary containment(material/design/listed) AST has integral secondary containment via a,system <br /> with primary sin le wall vessel set within a full containment inte ral outer goly shell to completely ca Lure <br /> any leaks from primary vessel. AST sits within a secured-covered lubricants basement lower level. Leak <br /> detection is visually ascertained via visual inspection of secondary containment area. The basement <br /> containment capacity is 69,000+gals gross containment, The basement area of this building which acts as an <br /> additional"tertiary"or third level containment was inspected is intact and AST is suitable for continued <br /> usage. <br /> 16. Damage to AST or systems. None reported. Upon inspection,no evidence of seam breaks unctures <br /> cracks,or other structural damage to the tank. Leak detection is assured via inspections of the secondary <br /> containment. Poly tank sits aside the steel waste oil tank within the containment basement. Poly <br /> thickness measured to 7.2 mm average thickness of poly tank outer shell. <br />