Laserfiche WebLink
Spill Prevention Compliance Corporation <br /> O Periodic Integrity Test Certificate <br /> P.O. Box 1289........Waterford, CA 95386 Telephone: (209) 969-0851 <br /> Email: NegM._,,hotmail.com <br /> Client: Chase Chevrolet Contact : Alex Robinson,Service Manner <br /> Address: 6441 Holman Rd. Phone No.: 209-475-6640 <br /> City/State/Zip; Stockton, CA 95212_ Date of Test: 10-9-19 <br /> Product Stored: Waste Oil-b UL#: P-77880 <br /> Tank Information(Brand/gallonage/Fuel Stored/UL or other serial#/miscellaneous) <br /> Containment Solutions/1500 gals/Waste Oi1/UL142/UL#P-77880/Double Wall Steel/14 yrs old(8/.2005) <br /> Description of Secondary Containment Integral Secondary Containment <br /> Date of Test 10-9-2019 Test Supervisor(s) Todd McWhorter <br /> METHOD OF PERIODIC INTEGRITY TEST-Primary XX Secondary XX <br /> 1.-Steel Thickness Test (in accordance with API-653 and/or UL 142 Std. (10 edition)-Readings Steel <br /> Thickness UL142 min. .167 in./Avg Steel thickness=.182 in. as measured (a,20 points on outer shell <br /> 2. Inert Gas Blanket <br /> Gas Used: Nitrogen ; CO2: ; Other(specify) <br /> Air Pressure-Test ; Vacuum Test ; <br /> Initial Reading (document psi/WC readings) Time <br /> End Readings (document psi/WC readings) Time <br /> Duration of Test: %drop <br /> 3. Sonar-Test_Y_N (document db readings) Duration <br /> 4. Camera(visual) model Lorex MC81845/interstitial (Result: PIF) Pass <br /> 5. Hydro-Carbon Sensor(probe) model OMNTEC BOA- _(Result: PIF) Pass <br /> 6. Hydrology (Water Column) (inches of water column readings).______ <br /> Duration % Drop Results (P/F) <br /> 7. Other: Inspect Vessel & secondary containment. AST clearance is 4 inches above floor. CRDM <br /> present, no evidence of leaking product from primary vessel,system accessible for inspection: No <br /> product in secondary. Tank has continuous electronic monitor& BJE TMl alarm. Upon inspection,no <br /> evidence of weld breaks,punctures,cracks,or other structural damage to the tank. Product supply is from 4 <br /> Graco Husky 1040 pneumatic pumas with bail valve manual shut downs. Steel thickness measured to.182 in. <br /> average, in excess of minimums required under UL 142. : PASS <br /> TEST RESULTS <br /> I'-Stage: <br /> Pass XX Fail_(quantify) SENSOR DETECTS NO PRODUCT NOR LEAKS FROM PRIMARY <br /> TANK INTO SECONDARY CONTAINMENT <br /> 2" -Stage: <br /> Pass XX Fail_(quantify) NO VISUAL EVIDENCE OF PRODUCT IN THE SECONDARY <br /> NOR OF ANY OTHER LEAKS/STEEL THICKNESS MEASURED N EXCESS OF UL142 <br /> MINIMUM STEEL THICKNESS STANDARD <br /> Comments section Tank is anchored to floor data on file <br /> Next Scheduled Periodic Integrity Test 6-28-24 <br /> �L(0 cZZ7 ''r `t/ ""� Pacific Environmental Systems,Representative <br /> Y P <br /> STI SP001 Certified Inspector No.: AST 135013 <br />