My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
6030
>
4800 – General/Other Program
>
PR0535206
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 8:24:37 AM
Creation date
6/30/2020 8:16:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4800 – General/Other Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0535206
PE
1862
FACILITY_ID
FA0019956
FACILITY_NAME
SILVESTRES CONST MECH CO
STREET_NUMBER
6030
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06105013
CURRENT_STATUS
01
SITE_LOCATION
6030 E KETTLEMAN LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
External Events Analysis PHA Lead By: Peter Thomas,P.E.,Resource Compliance <br /> SSHP Cold Storage Date: 6/16/2020 <br /> Ammonia Refrigeration System <br /> Potential to The Expected Date of Monitoring <br /> DetectionType of Create a Completion of any Changes Major Hazards Process Mitigation and <br /> External Magnitude or Scope of External Events Which Were Considered Release? Resulting From the Most Identified Controls in Systems in Systems in Since the <br /> Event (Yes/No) Recent Hazard Review or Use Use Use Last PHA <br /> PHA <br /> 2745.6(1)(1) 2745.6(1)(2) 2745.6(1)(3) 2745.6(e)(1) 2745.6(e)(2) 2745.6(e)(3) 2745.6(e)(4) 2745.6(e)(5) 2745.6(e)(6) <br /> 2745.7(q)(1) 2745.7(q)(2) 2745.7(q)(3) 2745.7(e)(1) 2745.7(e)(2) 2745.7(e)(3) 2745.7(e)(4) 2745.7(e)(5) 2745.7(e)(6) <br /> y Is equipment adequately protected from Yes-Neighboring facility(Delta Packing)has <br /> neighboring processes that could have a developed and implemented an No N/A <br /> ° hazardous materials release,explosion,or blast? RMP/PSM/CaIARP Program. <br /> a <br /> m <br /> o Are personnel adequately protected from Yes-Neighboring facility(Delta Packing)has <br /> Automatic Shut- Process Area <br /> a Offs,Manual Detector in <br /> s neighboring processes that could have a developed and implemented an No N/A <br /> m Toxic Release Shut-Offs, None Sheltered None <br /> Z hazardous materials release,explosion,or blast? RMP/PSM/CaIARP Program. Check Valves, Machinery <br /> E Relief Valves Area <br /> it If a neighboring process could have an explosion <br /> y or blast resulting in damage to your process,is Yes-Neighboring facility(Delta Packing)has <br /> equipment adequately protected from a developed and implemented an Yes N/A <br /> hazardous materials release? RMP/PSM/CaIARP Program. <br /> u Is equipment adequately protected from vehicular Yes-Equipmented is adequately protected Yes N/A <br /> m impacts? from vehicle impacts. Automatic Shut- Process Area <br /> Are procedures/practices in place to manage Toxic Release, Offs,Manual Detector in <br /> m vehicular movement(e.g.,cranes,trains, Equipment Shut-Offs, None Sheltered None <br /> vehicles)in process areas during all hours of the No-No specific procedure exists to manage Yes 8/13/2016 Failure Check Valves, Machinery <br /> day/night including in normal and inclement vehicular movement. Relief Valves Area <br /> weather? <br /> Is equipment adequately protected from extreme Yes-The refrigeration system was designed to Yes N/A <br /> a ambient high/low temperatures? account for high ambient temperatures. <br /> m <br /> Toxic Release, Automatic Shut- Process Area <br /> Is equipment adequately protected from flooding Equipment Offs,Manual Detector in <br /> c <br /> from internal as well as externals sources? Yes-Flooding is unlikely in this region. No N/A Failure, Shut-Offs, None Sheltered None <br /> E Overpressurizat Check Valves, Machinery <br /> v Are procedures/practices in place for removing ion Relief Valves Area <br /> N/A-No areas identified requiring rainwater <br /> rainwater from secondary containment areas in a No N/A <br /> timely manner and are they adequate? removal. <br /> v Are measures in place to minimize impacts to <br /> Yes-Most refrigeration equipment is located Automatic Shut- Process Area <br /> o process equipment due to a disgruntled Yes N/A <br /> a inside the machinery area. Offs,Manual Detector in <br /> employee? Toxic Release Shut-Offs, None Sheltered None <br /> Has a Security Vulnerability Assessment(SVA) No-Security Vulnerability Assessment(SVA) Check Valves, Machinery <br /> g <br /> been performed to evaluate potential impacts to is not required by DHS for ammonia No N/A <br /> process equipment? refrigeration processes. Relief Valves Area <br /> 3 <br />