My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
6030
>
4800 – General/Other Program
>
PR0535206
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 8:24:37 AM
Creation date
6/30/2020 8:16:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4800 – General/Other Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0535206
PE
1862
FACILITY_ID
FA0019956
FACILITY_NAME
SILVESTRES CONST MECH CO
STREET_NUMBER
6030
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06105013
CURRENT_STATUS
01
SITE_LOCATION
6030 E KETTLEMAN LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
External Events Analysis PHA Lead By: Peter Thomas,P.E.,Resource Compliance <br /> SSHP Cold Storage Date: 6/16/2020 <br /> Ammonia Refrigeration System <br /> Potential to The Expected Date of Monitoring <br /> DetectionType of Create a Completion of any Changes Major Hazards Process Mitigation and <br /> External Magnitude or Scope of External Events Which Were Considered Release? Resulting From the Most Identified Controls in Systems in Systems in Since the <br /> Event (Yes/No) Recent Hazard Review or Use Use Use Last PHA <br /> PHA <br /> 2745.6(1)(1) 2745.6(1)(2) 2745.6(1)(3) 2745.6(e)(1) 2745.6(e)(2) 2745.6(e)(3) 2745.6(e)(4) 2745.6(e)(5) 2745.6(e)(6) <br /> 2745.7(q)(1) 2745.7(q)(2) 2745.7(q)(3) 2745.7(e)(1) 2745.7(e)(2) 2745.7(e)(3) 2745.7(e)(4) 2745.7(e)(5) 2745.7(e)(6) <br /> Is equipment adequately protected from damage Yes-The likelihood of lightning striking <br /> y from lightning? ammonia equipment is low.Lightning storms Yes N/A <br /> y are unlikely in this region. <br /> 0 <br /> Yes-The likelihood of lightning striking <br /> Are personnel adequately protected from injury <br /> from lightning? personnel is low.Lightning storms are unlikely No N/A <br /> o <br /> Q_ in this region. <br /> ? Yes-The likelihood of lightning striking utilities Automatic Shut- Process Area <br /> Are utilities adequately protected from lightning orToxic Release, <br /> is low.Lightning storms are unlikely in this Yes N/A Offs,Manual Detector in <br /> static electricity? region. Equipment Shut-Offs, None Sheltered None <br /> Lu Failure, Check Valves, Machinery <br /> Are procedures in place for bonding and Explosion,Fire <br /> Yes-Lockout/tagout program is in place to Relief Valves Area <br /> n grounding material transfers to protect against control electrical energy. Yes N/A <br /> static energy accumulation and discharge? <br /> 'c <br /> z <br /> j Yes-Loss of power occurs occasionally and <br /> Are procedures in place to manage a partial or facility adapts accordingly.The system cannot Yes N/A <br /> complete loss of power and other utilities? <br /> be run during a power outage. <br /> Is equipment adequately protected from external Yes-Visual inspection revealed that flammable <br /> fire or explosion? and combustible materials are outside the Yes N/A <br /> sheltered machinery area. <br /> Automatic Shut- Process Area <br /> o No-Emergency Response/Action Plan Is in the Toxic Release, Offs,Manual Detector in <br /> X Are personnel adequately protected from injury process of being updated.Ensure that the plan <br /> w from fire or explosion? is updated,employees are training,and No 10/31/2015 Equipment Shut-Offs, None Sheltered None <br /> o Failure,Fire Check Valves, Machinery <br /> 0 coordination with first responders is conducted. Relief Valves Area <br /> it <br /> Are good housekeeping practices maintained to Yes-Machinery area and facility-at-large are <br /> minimize accumulation of flammable materials in maintained in a clean condition. Yes N/A <br /> process areas? <br /> a Is equipment adequately protected from <br /> neighboring facilities that could have a hazardous Yes-The facility is rurally located.There are no Yes N/A <br /> LL materials release,explosion,or blast? neighboring facilities. <br /> m <br /> Automatic Shut- Process Area <br /> Are personnel adequately protected from Yes-Neighboring facility(Delta Packing)has Offs,Manual Detector in <br /> o neighboring facilities that could have a hazardous developed and implemented an No N/A Toxic Release Shut-Offs, None Sheltered None <br /> z materials release,explosion,or blast? RMP/PSM/CaIARP Program. Check Valves, Machinery <br /> ERelief Valves Area <br /> w <br /> 0 If a neighboring facility could have an explosion Yes-Neighboring facility(Delta Packing)has <br /> @ or blast resulting in damage to your facility,is <br /> equipment adequately protected from a developed and implemented an Yes N/A <br /> hazardous materials release? RMP/PSM/CaIARP Program. <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.