My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_REMEDIATION COMPLETION REPORT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
29008
>
2900 - Site Mitigation Program
>
PR0539479
>
ARCHIVED REPORTS_REMEDIATION COMPLETION REPORT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2020 12:01:29 PM
Creation date
7/2/2020 9:18:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
REMEDIATION COMPLETION REPORT
RECORD_ID
PR0539479
PE
2950
FACILITY_ID
FA0022575
FACILITY_NAME
THORNTON DEHYDRATOR STATION
STREET_NUMBER
29008
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
THORNTON
Zip
95686
CURRENT_STATUS
01
SITE_LOCATION
29008 N THORNTON RD
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
415
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3.0 FIELD ACTIVITIES <br /> the final verification samples discussed below,sample identification was assigned based on <br /> the location and depth of the sample and the order in which the samples were collected. <br /> Sample identifications and locations were assigned on the basis of a"sample north" <br /> designation,running parallel to the eastern and western fence lines, and a"sample west," <br /> running parallel to the northern and southern fenceline (Figure 4).Approximate sample <br /> locations are shown on Figure 4 and referenced on Table 2. <br /> TPH-g and BTEX were below their respective detection limits in both hand auger samples. <br /> TPH-d was non-detect in sample 20-14.5W-115N-5.OHA at 5 feet bgs.The only detected <br /> concentration of TPH-d was 190 mg/kg in sample 20-14.5W-115N-9.5-HA at 9.5 feet bgs. <br /> TPH-mo was detected at 18 mg/kg in sample 20-14.5W-115N-5.OHA at 5 feet bgs,and was <br /> non-detect in the other hand auger sample. This area was not excavated based on access <br /> limitations due to the proximity of the active fiber optic line and due to property boundary <br /> issues. The analytical results and COC documents are presented in Table 2 and Appendix E, <br /> respectively. <br /> As with the hand auger samples,BTEX was non-detect for both samples collected from the <br /> test pit locations.TPH-g was non-detect in one sample and was reported at a concentration <br /> of 21 mg/kg in sample 20-42W-105N-5B at 5 feet bgs.TPH-d was detected at concentrations <br /> of 2,300 and 44 mg/kg in test pit samples 20-42W-105N-5B and 20-42W-11ON-5B,both at 5 <br /> feet bgs,respectively.TPH-mo was detected at 46 mg/kg in sample 20-42W-11ON-5B at 5 <br /> feet bgs,but was non-detect in the other sample.The soil in both of these test pit areas was <br /> removed during excavation activities based on this analytical data.The analytical results <br /> and COC documents are presented in Table 2 and Appendix E,respectively. <br /> 3.7.3 Verification Sampling <br /> Verification soil samples from the bottom and sidewalls of the excavation were collected <br /> and analyzed to document soil conditions prior to backfilling. The excavation was designed <br /> to remove the primary source of petroleum hydrocarbons to groundwater within the <br /> constraints of the excavation boundaries. <br /> A total of 33 final verification samples were collected from the excavation boundaries;16 <br /> were collected from the perimeter sidewalls and 17 from the base of the excavation.Sidewall <br /> samples were collected during excavation activities using the same methods described in <br /> Section 3.5.Sidewall samples were collected at depths of approximately 5 feet bgs and <br /> spaced laterally to result in one sample for every 20 linear feet.Due to excavation <br /> constraints as described in Section 3.6, all sidewall samples were considered final and no <br /> additional samples were collected. <br /> Seventeen bottom samples were collected to provide approximately one base sample for <br /> every 20-foot by 20-foot area. Actual sample locations were determined in the field based on <br /> observed removal of petroleum staining and/or odor. <br /> Soil samples were analyzed for the same parameters outlined in Section 3.7.2. Table 3 <br /> summarizes verification soil sample analytical results.Analytical reports and COC <br /> documents are provided in Appendix E. Analytical results for BTEX and TPH in soil were <br /> evaluated to assess whether further excavation was needed prior to backfilling the <br /> excavation areas. <br /> SF01(THORNTON COMPLETION REPORT_621-05.DOC) 3.5 <br />