Laserfiche WebLink
Page 6 of 7 <br /> P. Procedure for an Accidental Spill: Describe the clean up and disinfection procedure taken when there <br /> is an accidental spill of sharps. <br /> The person that cleans the spill will put on their protective equipment before cleaning the spill. Once <br /> the protective equipment is on, all sharps will be picked up and placed back into the sharps container. <br /> All of the outside surfaces of the container is then sprayed with a cide and allowed to soak for 3-5 <br /> minutes before being placed back on the wall mount. The area where the sharps spilled is also sprayed <br /> with a cide and allowed to soak for 3-5 minutes before being wiped down and scrubbed with soap and <br /> water. After the scrubbing, all surfaces are sprayed again with a cide and allowed to soak for 3-5 <br /> minutes before being wiped. If the sharps spilled n the floor,the floor is mopped once it has been <br /> disinfected. <br /> Q. Trash Receptacles and Disposal of Contaminated Trash: List the type of trash receptacles and their <br /> location throughout the body art facility. Describe the procedure for the disposal of contaminated items, <br /> such as gloves. <br /> All procedure room trash receptacles are metal and have a closing lid. The trash receptacles in the <br /> lobby and restrooms are plastic. The trash receptacle in the sterilization room is metal and has a closing <br /> lid. Gloves are thrown into the trash receptacles that are in the rooms where they were used. All trash <br /> receptacles are emptied when they are full and at the end of the day. <br /> R.Negative/Failed Spore Test: Describe the procedure conducted when a monthly spore test has failed. <br /> Indicate whether the facility maintains a spore test log on-site. <br /> If a spore test fails, we would check the log book for the date that it was autoclaved on before it was <br /> mailed in for testing. A sterile log book would reveal who was responsible for operating the autoclave <br /> on that particular day. We would check to see what the temperature and pressure was during the load to <br /> find out if any of the knobs were adjusted before the load was ran or if there was a sufficient amount of <br /> water in the chamber at the time it was ran. The integrator would also be checked to make sure it passed. <br /> If any repairs needed to be made to the autoclave they would be taken care of before it was used again. <br /> Also, all tools and equipment that were autoclaved before the failed test would immediately be taken out <br /> of circulation until the autoclave is repaired and a spore test passes. During the time that the tools and <br /> equipment are taken out of circulation, single use disposable tools and equipment will be used. This <br /> facility does keep a spore test log on site. <br /> S. Commercial Ink or Pigment Manufacturers: List the manufacturer for the inks or pigments used at the <br /> body art facility. Describe the procedure for dilution of inks. Only sterile water should be used for <br /> dilution of inks or pigments. <br /> Kingpin,National, Eikon, Mithra, Lucky Tattoo Supply, and Tat soul are the main companies that <br /> this facility uses to purchase inks and pigments from. Only sterile water is used for the dilution of inks <br /> or pigments. <br /> T. Permanent Cosmetic Machine Name and Manufacturer: This facility does not perform cosmetic <br /> tattoos. <br /> U. Service Animals: Describe the facility's policy regarding service animals allowance in procedure or <br /> decontamination and sterilization areas. <br /> There are no animals allowed in this establishment at any time. If a person needed a service animal <br /> such as a seeing eye dog they would be asked to leave and return with a person to assist them. <br /> 1/22/2013 <br />