8.Tattoo machine and clip cords:All tattoo machines and clip cords are sprayed down <br /> with a cide and allowed to soak for 3-5 minutes before being wiped down,before and after <br /> all tattoos. <br /> 9.Reusable instruments,calipers,needle tubes, etc.,portable light fixtures or other: <br /> All reusable instruments,calipers,and needle tubes are immersed in a cide and allowed to <br /> soak for 3-5 minutes after each use or if their packaging/seal is ripped or opened and then <br /> sterilized again.Portable light fixtures are sprayed with a cide and allowed to soak for three <br /> to five minutes before being wiped down at least once daily <br /> 10.Permanent cosmetic machine:we do not perform any cosmetic tattooing therefore <br /> we do not own any cosmetic tattoo equipment. <br /> B. Reusable Instruments or Disposable: Describe the procedures used for <br /> decontaminating, sterilizing,packaging and storing of reusable instruments. Include the <br /> procedures for labeling of sterilized peel-packs. Indicate whether the body art facility uses <br /> all pre-sterilized, single use and disposable instruments.Describe the record keeping logs <br /> and procedure logs maintained on-site when using 100%pre sterilized,single use and <br /> disposable instruments. <br /> 1.Needle tubes:Most needle tubes are single use and pre-sterilized. Once a <br /> pre-sterilized needle tube has been used it is thrown away. All invoices from ordering <br /> pre-sterilized needle tubes and needles are kept on site. The backs of all of the peel packs <br /> for pre-sterilized needle tubes and tattoo needles area hed to the back of the release <br /> form after it has been filled out.Every release form is held on site for at least ninety days <br /> and then taken to an offsite storage location.Needle tubes that are reusable are submerged <br /> in a cide and allowed to soak for 3-5 minutes before being placed in an ultrasonic machine <br /> after each tattoo. The tubes will run a cycle for a minimum of 60 minutes in the ultra-sonic <br /> machine in a solution such as cross- e.After the cycle in the ultra-sonic,the tubes are <br /> manually washed with a mixture of soap and water and then allowed to air dry.After the <br /> tubes are completely dried,they are individually packaged and labeled with the date, <br /> person's initials that prepared them,the to number and then put into the autoclave for <br /> sterilization.Reusable sterilized tubes are stored in sealable/closing plastic containers in or <br /> near the workstation but kept away from the cleaning room. <br /> 2. Calipers: The calipers used at this facility are reusable. After each use,all calipers <br /> are soaked in a cide for 3-5 minutes. After the soaking is complete,the calipers are <br /> manually washed with a mixture of soap and water.After the washing is complete the <br /> calipers are rinsed thoroughly and then allowed to air dry.Once the calipers are completely <br /> dried,they are individually packaged and labeled with the date,person's initials that <br /> prepared them,the load number and then put into the autoclave for sterilization.Reusable <br /> sterilized calipers are stored in scalable/closing plastic containers in or near the <br /> workstation but kept away from the cleaning room. <br />