My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1980-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FAIRMONT
>
975
>
4500 - Medical Waste Program
>
PR0450003
>
COMPLIANCE INFO_1980-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2026 2:54:44 PM
Creation date
7/3/2020 10:17:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4500 - Medical Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1980-2010
RECORD_ID
PR0450003
PE
4522 - ACUTE CARE FACILITY
FACILITY_ID
FA0000513
FACILITY_NAME
LODI MEMORIAL HOSPITAL
STREET_NUMBER
975
Direction
S
STREET_NAME
FAIRMONT
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
03107039
CURRENT_STATUS
Active, billable
SITE_LOCATION
975 S FAIRMONT AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
FilePath
\MIGRATIONS\MW\MW_4522_PR0450003_975 S FAIRMONT_1980-2010.tif
Site Address
975 S FAIRMONT AVE LODI 95240
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
219
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Control # <br />1446 <br />Building <br />Lodi Memorial Hospital <br />Description <br />STERILIZER, WASTE <br />Location <br />OUTSIDE <br />Manufacturer <br />Mark Costello <br />Class <br />WST STER <br />Model <br />AS -46 <br />Issue Date <br />11/1/2005 Due 12/31/2005 <br />Serial <br />LAAT-975 <br />Assigned to <br />Cost Center <br />8460 Plant Maintenance <br />Risk <br />2 Critical <br />Equipment <br />Notes <br />Instructions <br />Safety <br />Inspection <br />Performance Allow the sterilizer to stablize at the set temperature. Using a calibrated thermometer, verify the <br />Inspection temperature displayed on the chart recorder is within +0/ -5 degrees F. Record temperature accuracy <br />in the service notes. <br />Forward copy of of report to Donna. <br />Preventive CLEAN AND CHECK OVERALL CONDITION <br />Maintenance GREASE DOOR AND LATCH <br />GREASE CART CASTERS <br />REMOVE DEBRI FROM DRAIN INSIDE VESSEL (DO NOT ENTER!) <br />REMOVE STRAINER AND CLEAN <br />VERIFY STEAM PRESSURE AND RECORD 38 LBS. MINIMUM <br />Parts <br />Replacement <br />Service Date Tech Hr Service Notes <br />11/7/2005 Duncan 3.50 Using a calibrated thermometer the temperature accuracy was <br />within 2 degrees. Replaced chart cover door & steam pressure <br />guage. <br />Complete W Closed By duncti Date 11/7/2005 Hours <br />
The URL can be used to link to this page
Your browser does not support the video tag.