My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9069
>
4400 - Solid Waste Program
>
PR0440001
>
COMPLIANCE INFO_1996-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2021 8:55:58 AM
Creation date
7/3/2020 10:39:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2003
RECORD_ID
PR0440001
PE
4433
FACILITY_ID
FA0004514
FACILITY_NAME
AUSTIN ROAD/ FORWARD LANDFILL
STREET_NUMBER
9069
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
9069 S AUSTIN RD
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440001_9069 S AUSTIN_1996-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
623
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM NO. R5-2003-0049 9 <br /> FORWARD INC AND ALLIED INDUSTRIES <br /> FOR OPERATION OF <br /> FORWARD CLASS 11 LANDFILL <br /> SAN JOAQUIN COUNTY <br /> the facility on the unsaturated zone and compliance with the Water Quality <br /> Protection Standard. <br /> 3. Leachate Monitoring <br /> All Unit leachate collection and removal system sumps shall be inspected monthly <br /> for leachate generation. Upon detection of leachate in a previously dry leachate <br /> collection and removal system, leachate shall be sampled immediately and <br /> analyzed for the constituents listed in Table III. Leachate shall then be sampled <br /> and analyzed annually during the fourth quarter thereafter, with a retest during the <br /> following second quarter if constituents are detected that have not been previously <br /> detected. Leachate samples shall be collected and analyzed for-the listed <br /> constituents in accordance with the methods and frequency specified in Table Ell. <br /> The constituents of concern list shall include all constituents listed in Table VI. <br /> The quantity of leachate pumped from each sump shall be measured and reported <br /> monthly as Leachate Flow Rate (in gallons). <br /> Leachate which seeps to the surface from the Unit shall be sampled and analyzed <br /> for the constituents listed in Table III upon detection. The quantity of leachate <br /> shall be estimated and reported as Leachate Flow Rate (in gallons/day). <br /> 4. Surface Water Monitoring <br /> Littlejohns Creek shall be sampled upstream of the landfill at background <br /> monitoring point SW-1, and downstream at monitoring point SW-2. Surface <br /> water samples shall be collected quarterly when water is present. Samples shall <br /> be collected from all stations and analyzed for the monitoring parameters <br /> specified in Table IV. All surface water monitoring samples shall be collected <br /> and analyzed for the constituents of concern specified in Table IV every five <br /> years. Annually, all monitoring parameters shall be graphed so as to show <br /> historical trends at each sample location. <br /> 5. Landfill Gas Monitoring <br /> The discharger shall install, expand as needed, and operate a landfill gas <br /> monitoring system in accordance with a landfill gas detection monitoring plan <br /> approved by the Executive Officer. Landfill gas monitoring points shall be <br /> sampled and analyzed for the monitoring parameters specified in Table II. The <br /> Discharger shall collect, preserve, and transport samples in accordance with the <br /> quality assurance/quality control standards contained in the approved Sample <br /> Collection and Analysis Plan. <br />
The URL can be used to link to this page
Your browser does not support the video tag.