My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WAVERLY
>
6484
>
4400 - Solid Waste Program
>
PR0440004
>
ARCHIVED REPORTS
>
ARCHIVED REPORTS_2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:21 PM
Creation date
7/3/2020 10:41:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2003
RECORD_ID
PR0440004
PE
4433
FACILITY_ID
FA0004517
FACILITY_NAME
FOOTHILL LANDFILL
STREET_NUMBER
6484
Direction
N
STREET_NAME
WAVERLY
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
09344002
CURRENT_STATUS
01
SITE_LOCATION
6484 N WAVERLY RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440004_6484 N WAVERLY_2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
996
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Foothill Sanitary landfill — Module 1 December 2003 <br />County of San Joaquin Job No 031602 00 02 <br />0 Table 6 — Geotextile Conformance Testing Summary <br />5.4.3 Deployment <br />The panel deployment procedure was observed and documented by Vector's CQA <br />Monitor. Our CQA Monitor verified that the conditions of the CQA manual were met <br />during deployment. <br />5.4.4 Seams and Overlaps <br />Seam overlap, seaming, tie-ins, and other manufacturer's written guidelines were <br />followed in accordance with the project specifications. <br />Vector Engineering, Inc. - 143E Spring Hill Drive - Grass Valley, CA 95945 - (530) 272-2448 <br />36 <br />Test Results <br />ASTM D-5261 <br />ASTM D-4632 <br />ASTM D-4833 <br />ASTM D-4491 <br />ASTM D-4751 <br />Sample <br />No. <br />Mass per Unit <br />Area <br />(oz/yd2) <br />Grab Tensile <br />Strength <br />(Ibs) <br />MD/TD <br />Puncture <br />Resistance <br />(Ibs) <br />Water Flow <br />Rate <br />(gal/min/ft2) <br />Apparent <br />Opening Size <br />(mm) <br />P/F <br />SPEC. <br />>8.0 <br />>220 <br />>130 <br />>110 <br />< 0.21 <br />-- <br />130150394 <br />8.7 <br />271/299 <br />156 <br />130 <br />0.207 <br />P <br />130150416 <br />8.5 <br />253/309 <br />162 <br />127 <br />0.202 <br />P <br />130150438 <br />8.9 <br />257/284 <br />156 <br />127 <br />0.205 <br />P <br />130150797 <br />8.4 <br />285/354 <br />170 <br />136 <br />0.204 <br />P <br />130151042 <br />8.6 <br />271/300 <br />169 <br />136 <br />0.202 <br />P <br />0151064 <br />9.0 <br />251/328 <br />157 <br />131 <br />0.202 <br />P <br />130151086 <br />8.9 <br />270/300 <br />157 <br />137 <br />0.206 <br />P <br />130151130 <br />8.7 <br />250/296 <br />161 <br />134 <br />0.206 <br />P <br />5.4.3 Deployment <br />The panel deployment procedure was observed and documented by Vector's CQA <br />Monitor. Our CQA Monitor verified that the conditions of the CQA manual were met <br />during deployment. <br />5.4.4 Seams and Overlaps <br />Seam overlap, seaming, tie-ins, and other manufacturer's written guidelines were <br />followed in accordance with the project specifications. <br />Vector Engineering, Inc. - 143E Spring Hill Drive - Grass Valley, CA 95945 - (530) 272-2448 <br />36 <br />
The URL can be used to link to this page
Your browser does not support the video tag.