Laserfiche WebLink
Landfill staff periodically inspects the cover on filled modules for low spots that could allow for <br />ponding water and directs the operator to correct this condition. <br />Module "I" does not have a leachate collection and recovery system. - <br />Module 1 and all future modules will include leachate collection and recovery systems (LCRSs) <br />Leachate in Module 1 drains by gravity to the sump located in the southeast <br />corner of the module from which it is pumped either to the 10 000 -gallon storage <br />tank or returned to the refuse over an approved liner in accordance with the <br />WDRs. <br />Leachate that is generated from Module 1 flows to a leachate sump from which it is pumped <br />either to a storage tank or returned to the refuse fill in accordance with the WDRs. Leachate <br />from the storage tank is ultimately returned back to the waste in the lined modules in <br />accordance with the Waste Discharge Requirements, or -As applied to surfaces over lined <br />modules by water truck. <br />Foothill Sanitary Landfill Page 96 Public Works/Solid Waste <br />Joint Technical Document County of San Joaquin — Revised 7/30/10 <br />