My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2002 - JTD
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2002 - JTD
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2023 12:46:56 PM
Creation date
7/3/2020 10:48:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2002 - JTD
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
953
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
maintenance period. Included as part of the survey information, an iso - <br />settlement map and report is to be submitted to the RWQCB. <br />A slope stability analysis is required by 27 CCR, Section 21090 when the <br />closure design includes final slope faces steeper than 3:1 (horizontal to <br />vertical) or a synthetic component in the final cover configuration. The <br />proposed final slopes for the Forward Landfill do not exceed 3:1 and a <br />synthetic component is not proposed, but the slope below the proposed 15 - <br />foot wide bench has an inclination of 2:1 (horizontal to vertical). Therefore, a <br />slope stability analysis was conducted pursuant to 27 CCR, Section <br />21750(f)(5) to review the integrity of final slopes under both static and <br />dynamic conditions. The results of the slope stability analysis are included in <br />To evaluate the static stability of the proposed refuse cover system at various <br />design inclinations and slope heights, the proposed cover configuration was <br />analyzed by typical force equations. For this case, the soil cohesion was <br />neglected. Static refuse cover slope stability (assuming a failure at the <br />cover/MSW interface) for all three slope inclinations analyzed indicates a <br />factor of safety greater than 1.5 <br />To analyze the cover layer itself, the infinite slope method was utilized. This <br />analysis assumes that the failure takes place within the soil cover itself. Two <br />cases were analyzed: unsaturated and fully saturated. Static refuse cover <br />slope stability for the steepest proposed slope inclination of 3.2:1 (horizontal <br />to vertical) indicates an unsaturated factor of safety of 2.31 (typically has to <br />be greater than 1.5) and a saturated factor of safety greater than 1.3 (typically <br />a saturated factor of safety of 1.1 to 1.2 is adequate). <br />The proposed 2:1 (horizontal to vertical) slope below the 15 -foot wide <br />benches was analyzed for static and dynamic stability by the use if the <br />computer program SLOPEM/. The results of the static stability analysis <br />indicate a factor of safety of 1.92. <br />The three proposed cover inclinations and heights were analyzed for dynamic <br />displacement. For analysis of the dynamic condition, the cover configuration <br />Forward Landfill PFCPCMP 3-9 <br />Z:\PROJECTS\Allied Waste\Forward\Reference Files Prior JTD\June 05 Stage IA Partial FCPCMP\FL-sec3.doc: 6/16/2008 <br />
The URL can be used to link to this page
Your browser does not support the video tag.