My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2002 - JTD
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2002 - JTD
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2023 12:46:56 PM
Creation date
7/3/2020 10:48:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2002 - JTD
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
953
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Conditions for N-339-17-10 (continued) <br />Page 4 of 9 <br />42. Annual amount of soil used for intermediate and final covering shall not exceed 1,406,527 cubic yarcls of soil, and <br />PM 10 emissions shalt not cxc=tl 0.0061b PM 10/ton of soil (using, a soil density of 3,240 lbs/cubic yard of soil). <br />Permittee shall keep annual records of the amount of soil used for intermediate and final covering, (District NSR Rule) <br />Fedcrully )enforceable Through Title V Permit <br />43. Permittee shall maintain daily and annual records otlandfill gas flow rate to the flares. [District Rule 10701 Federally <br />Enforceable Through Title V Permit <br />44. All records shall be retained for a period of at least 5 years and shall be made available for District inspection upon <br />request. (District R.ulc 10701 Federally Enforceable Through Title V permit <br />45. A record of continuous flare combustion temperature, continuous volumetric gas flow rate, net heating value of landfill <br />gas being combusted, daily average fuel consumption, daily average heat input, and carbon canister inspection shall be <br />maintained, retained on the premises for a period of at least five years and made readily available for District <br />inspection upon request. [District NSR Rule] federally Fnforccablc Through Title V Permit <br />46. This opcniting permit may be cancelled with APCO approval when the landfill is closed, pursuant to the requirements <br />of this permit, if IN; landfill is not otherwise subject to the requirements of either 40 CFR part 70 or part 71 and if <br />either 1) it was never subject to the requirement for a control system tinder 40 CFR 60.752(b)(2); or 2) the owner or <br />operator meets the conditions for control system removal specified in 40 CFR 60.752(b)(2)(v). [40 CFR 60.752(d)] <br />Federally Enforecable'Through Title V Permit <br />47. If the landfill is permanently closed, a closure notification shall be submitted to the APCO within 30 days of waste <br />disposal cessation. A permanent closure must take place in accordance with 40 CI:R 258.60. if a closure report has <br />been submitted, no additional waste may be placed in the landitlI without tiling a notification of modification to the <br />APCO, pursuant to 40 CFR 60.7(a)(4). [40 CFR 60.752(b)(1)(iiXR), 60.757(4)) <br />4S. An active collection system shall be designed to handle the maximum expected gas Clow rate from the entire area of <br />the landfill that warrarnt.s control over the intended use period of the gas control or treatment system equipment, collect <br />has from each area, cell, or group of cells in the landfill in which the initial solid waste has tint placed for a period of <br />5 years or more if active; or 2 years or more if closed or at final grade, collect gas at a sufficient extraction rate, and be <br />designed to minimiic; off-site migration ofsubsurfacc gas. [40 CYR 60.752(b)(2)(ii)(A)] Federally rinlorceable <br />Through Title: V Permit <br />49. All collected gas shall be routed to a control system designed and operated to reduce the NMOC by 99 weight percent <br />or reduce the outlet NMOL concentration to less than 20 parts per million by volume, dry basis as hexane at 3 percent <br />oxygen. The reduction efficiency shall be established by an initial performance test w be completed no later than 180 <br />days after the initial startup of the approved control system using the test methods specified in Section 60.754(4). [40 <br />CFR 60.752(bx2)(iii)(B)] Federally Enforceable Through Title V Permit <br />50. Permittee shall operate the collection system so that the methane concentration is less than 500 parts per million above <br />background at the surface of t.hc landfill. To determine if this level is exceeded, the owner or operator shall conduct <br />surface tcating around the perimeter of the collection area and along a pattern that traverses the landfill at 30 meter <br />intervals and where visual observations indicate elevated concentrations of landfill gas, such as distreswd vegetation <br />and cracks or seeps in the cover. The owner or operator may establish an alternative traversing pattern that ensures <br />equivalent coverage. A surface monitoring design plait shall be developed that includes a topographical map with the <br />monitoring route and the rationale for any site-specific deviations from the 30 meter intervals. Areas with steep slopes <br />or other dangerous areas may he excluded from the surface testing. [40 CFR 60.753(d)] Federally Enforccablc <br />Through Title V Permit <br />51. Compliance with this surface methane operational standard shall be demonstrated using the procedures outlined in 40 <br />CFR 60.755(c) within 180 days of installation and startup of the collection and control system and quarterly thereafter. <br />(40 CFR 60.753(d), 40 CFR 60.755(c), and 40 CFR 60.6] Federally Enforecabic Through 11de V Permit <br />52. Pumiittc a shall operate the enclosed flare at all times when the collected gas is routed to it. [40 CFR 60.753(01 <br />federally Enforceable Through Title V Permit <br />53. Pcrmittcc shall operate the landfall gas collection system such that gas is cullcctcd from each area, cell, or group of <br />cells in the MSW landfill in which solid waste has been in place for- (1) five years or more if active; or (2) two years <br />or more if closed or at final graft. [40 CFR 60.753(a)] Federally Enforceable Through Title V Permit <br />CONDITIONS CONTINUE ON NEXT PACE <br />•a».v.,r-+,..•to.r roam.—gar <br />
The URL can be used to link to this page
Your browser does not support the video tag.