Laserfiche WebLink
In the past, Forward has implemented programs for treating both gasoline and <br /> nonvolatile petroleum hydrocarbon contaminated soil. A brief operations <br /> summary for treatment of both of these contaminated soil types follows. <br /> Treatment of Nonvolatile Petroleum Hydrocarbon Contaminated Soil <br /> The "Operation and Maintenance Manual, Soil Treatment System, Forward, Inc., <br /> Landfill Unit WMU G, Stockton, California" (Harding Lawson Associates, April <br /> 1991) describes the treatment system for nonvolatile petroleum hydrocarbon <br /> contaminated soils. The specifications and reporting requirements of the <br /> treatment system are specified in the WDRs, Order No. R5-2003-0049 and in the <br /> October 31, 1990, letter from S)CPHS to Forward. <br /> The contaminated soil treatment system consists of an area where appropriate <br /> fertilizers are added to the contaminated soil and the soil is mechanically aerated <br /> to accelerate biodegradation of hydrocarbons (bioremediation process). The <br /> objective of the treatment process is to biodegrade the hydrocarbons to levels <br /> appropriate for landfilling. After the contaminated soils have been adequately <br /> treated, the soil can be used for daily cover, intermediate cover, or foundation <br /> layer for the closure cap. If necessary, the treated soils can be disposed in a <br /> Class II or Class III WMU. <br /> Although there are currently no Land Treatment Units (LTUs) at the site, LTUs have <br /> been constructed in the past and may be utilized in the future. LTUs for contaminated <br /> soil are permitted within WMU G-North or G-South. The units are approximately <br /> 40 feet wide by 500 feet long. The number of operating LTUs at any given time will <br /> vary according to the market need for the soil treatment process. Previously <br /> constructed LTUs have consisted of a 40-mil polyvinyl chloride (PVC) liner covered <br /> with a 6-inch-minimum thickness layer of sand and gravel, an 18-inch minimum <br /> thickness layer of compacted clay, and a 6-inch-minimum thickness layer of a sand and <br /> gravel buffer zone. A layer of contaminated soil approximately 18 inches thick is <br /> placed within each LTU for treatment. <br /> Berms contain stormwater within the LTUs, and a drainage system removes storm- <br /> water that accumulates. The surfaces of the LTUs will be sloped so that excess <br /> rainwater drains to a storage tank. Water stored in the tank will be used for soil <br /> moisture control during the treatment process or pumped to the leachate evaporation <br /> pond. <br /> Forward Landfill JTD 6-14 <br /> 1:\Allied\Forward\JTD Amendment\January 2007 JTD Amendment\JTD Sec 6 Final.doc: <br /> 5/22/02;Rev. 1:7/2002:Rev.2:4/2003;Rev 3:6/2003; .Amendment No. 1:2/1/2007 BRYAN A.STIRRAT&ASSOCIATES <br />