My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2005_2
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2005_2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:23 PM
Creation date
7/3/2020 10:49:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2005_2
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2005_2.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
150
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
On the basis of the soil conditions modeled, soils suitable for use in the FSL closure final <br /> cover can be generated by select excavation of soils from the proposed borrow source <br /> adjacent to the site. In order to generate adequate performance characteristics, the final <br /> cover materials should be mixed to exhibit a grain size distribution that generally <br /> excludes particles in excess of 3 inches. In addition, soil excavation and placement <br /> operations should be conducted so as to yield a minimum fines content(%by weight <br /> passing the No. 200 sieve) of 70, a minimum of at least 30% finer than 5-microns and an <br /> as-built saturated hydraulic conductivity of less than 1x10-6 cm/s. <br /> As indicated above, sufficient borrow materials are likely to be available from the borrow <br /> source to meet the project specifications (Figure 1). A quality assurance plan describing <br /> the materials testing methods and procedures, testing frequencies, and materials <br /> specifications for an alternative final cover system placed over the FSL is presented as <br /> Appendix D. Moisture monitoring should be conducted in accordance with the <br /> recommendations presented in the monitoring workplan (Appendix E). <br /> 7.0 CONCLUSION <br /> Based on the data presented herein, it is concluded that a 4-foot thick monolithic final <br /> cover section constructed as described above will satisfy the regulatory requirements for <br /> an alternative final cover as defined in CCR Title 27. More specifically, the conditions <br /> summarized above are believed to effectively demonstrate that a prescriptive cover is not <br /> feasible at this site and that the proposed alternative final cover will provide equivalent <br /> protection against water quality impairment at a reduced cost. <br /> 8.0 CLOSURE <br /> This report is based on the project as described and the geotechnical data obtained in this <br /> study. Our firm should be notified of any pertinent change in the project plans or if <br /> conditions are found that differ from those described in this report, since this may require <br /> a revaluation. This report has not been prepared for use by parties or projects other than <br /> those named or described above. It may not contain sufficient information for other <br /> parties or other purposes. <br /> This report has been prepared in accordance with generally accepted geotechnical <br /> practices and makes no other warranties, either express or implied, as to the professional <br /> advise or data included in it. <br /> Geologic Associates <br /> Gl <br /> ?Luis A, Mcanscal Gary L. Lass, RG, EG, HG <br /> Staff Engineer, EIT President <br /> LAM/GLL/lkl <br /> -12- <br /> C:\2005-0082\FOR WARD/ForwardCOVER.DOC\7/t.U2005 <br /> Geologic Associates <br />