My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2006_1
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2006_1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:23 PM
Creation date
7/3/2020 10:50:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2006_1
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2006_1.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
641
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'as little agitation as possible to reduce potential loss of volatile constituents. Major ions, 'DS, <br /> and metals analyses (n non-preserved containers) will be collected next followed by samples to <br /> be collected in preserved containers. Containers will be filled directly from the disposable bailer, <br /> immediately capped,and placed in a temperature-monitored iced chest. Caution will be , <br /> used not <br /> to overfill bottles containing a ps�eservvative. Temperature will be monitored by Pl;tctrig. a <br /> 6ennometer in the chest and.checking to make'sure thatthere is suffidcnt ice :the chest to <br /> e .e a temperature of awdmatel 4 d i - <br /> APP Y . degrees Celsius. The labOratoly will measure; <br /> document,and report the temperature of the sample container upon anival at the gyratory.. <br /> The.analytical laboratory places a total of 2 ml of nitric acid in some of 2tie 1 liter bottles to <br /> reduce the pH to below 2, On an annual basis.an extra preserved bottle will be filled with <br /> .groundwater and-the pH measured in the bottle. It is'assumed that the pH will be below 2 If it <br /> is not the field technician will add nitric acid in measured amounts until the pH is below 2 This <br /> added quantity of acid will be placed in all the preserved bottles-during the following monitoring <br /> rounds until it is checked again the following-y tar Sample..pH•-will- bc.confirm,-d-at.the•.: <br /> laboratory and recorded. Deviations will be documented and reported by the laboratory. <br /> Samples.to be su$mitted for metals analysis-will. be filtered in the field- Filtering-,vi11 be <br /> �-'- performed using an in.line,filter mechanism which uses the pumpingProcess of the dedicated <br /> fie pump to draw water through the 4 micron*fHier- Anever filter will be used at each well. The new <br /> filters -Mll have a minimum of one filter volume of groundwater pressuri d through them to- <br /> re duce adsorption effects. The actual filtered.sample.will not be collected-until aminimum of <br /> two fiber volumes of groundwater ha:5 been passed through tha filter. � For wells wi6out <br /> dedicated pumps, the samples are transferred from the bailer;through a filter apparatus, into the <br /> appropriate sample container_ The filter apparatus consists of a Pressure vessel,a hand-operated <br /> Pressure pump, and a filter cartridge. Water from the bailer is placed in the pressure vessel and <br /> enough air,pressure(via the hand pump)is appliiad to force water through the filter cartridge into <br /> sample mple bottles. The pressure vessel is washed in Aleonox, steam cleaned, and rinsed with <br /> deionized water between wells_ A new filter cartridge is used at each well. <br /> Samples will. be labeled with a unique sample identification number, project identification <br /> number, sample location, and date and time sampled. Samples will be transpo_rte:d to the contract <br /> laboratory under strict chain-of-custody procedures__ <br /> 23 83849- <br /> -4 . F0112310R32S M9 <br /> July 14,2Q00 <br /> Copy I&2000 KkWelder.taw <br />
The URL can be used to link to this page