My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2006_21
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2006_21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:25 PM
Creation date
7/3/2020 10:51:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2006_21
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2006_21.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ms. Christina Carbajal <br /> July 19,2006 <br /> Page 4 <br /> Also, on June 6, 19,and 29, 2006,SCS continued monitoring/adjustment to,recently installed by <br /> others, LFG Extraction Well Nos. FOFU-0304-Well, FOFU-04-06 through FOFU-04-1.2,FOFU- <br /> HCO1,FOFU-04-LCR, FOFU-05.06 and FOFU-05HC1 in attempts to maintain the observed <br /> methane gas concentrations detected at GP-11 and GP-12 to below the LEL as directed by the <br /> client. SCS will continue to adjust wells as directed by Allied.personnel. <br /> Finally, during this reporting period,temperatures at LFG extraction wells were monitored and <br /> observed to range from 78 to 114 degrees Fahrenheit(see Table 2). These temperatures are <br /> considered to be in the normal to upper range for anaerobic decomposition. SCS will continue to <br /> test LFG temperatures at each extraction well on a monthly basis in order to develop a database. <br /> This additional information should provide a better understanding of subsurface conditions at the <br /> site. <br /> ]LFG Collection System <br /> Visual observation of the LFG collection system is conducted twice per month, During these <br /> visits.,observations are made to ensure no pipe brrAkages have occurred and condensate drain, <br /> sumps remain functional. Minor repairs are completed as required. <br /> On June 6, 14, 19 and 29,2006, SCS performed monitoring of all accessible LFG Condensate <br /> Sumps Nos.ARTP-1 through 7 and FOTP-8 through 19 for proper operation. <br /> In addition, on June 6, 2006 and as previously reported, SCS obsen ed an,elevated oxygen gas <br /> concentration in the below grade main pipeline between LFG Condensate Sump Nos. FOCS-10 <br /> and FOCS-11, indicating a possible separation..As of the date of this report, SCS performed the <br /> necessary repairs restoring proper operation. <br /> In.addition, during pervious reporting periods, SCS observed and repaired several slight air supply <br /> and/or liquid leaks at several LFG condensate sumps. As requested by the Client,SCS has <br /> prepared a proposal dated august 5,2004, and recommends that the existing air and <br /> condensate connections be modified to decrease the potential for future separations/air leafs, <br /> Finally, SCS routinely conducts a pressure drop survey(i.e.,measurement of main pipeline <br /> pressure at various points throughout the LFG collection system). The results of this survey <br /> indicated that no major restrictions within the LFG collection.,system currently exist and all <br /> accessible extraction wells are receiving adequate vacuum. <br /> LFG SlowerlF'lare Station{BF'S) <br /> Visual observations and testing of the LFG BFS was conducted on June 6, 14, 19 and 29, 2006. <br /> During these visits,operating parameters are monitored and mechanical and electrical components <br />
The URL can be used to link to this page
Your browser does not support the video tag.