Laserfiche WebLink
WMU FU-06 November 2006 <br /> Forward Landfill Project No.021605.07 <br /> Upon completion of excavation of the sump, porous suction cup lysimeters were <br /> placed in the subgrade beneath the sump. Vector's CQA Monitor observed that the <br /> Contractor tested the lysimeters to ensure their functionality prior to covering them <br /> with subsequent materials. <br /> 4.2 Subgrade Fill <br /> Subgrade fill is defined as the material placed on the 5:1 north slope overlying the <br /> former Austin Road Landfill. Subgrade fill material was placed in maximum 8-inch <br /> loose lifts and compacted with a CAT 815 sheepsfoot compactor. Moisture was <br /> added in place with a water truck and mixed into the soil with a road grader. After <br /> the fill material was compacted, field density tests were conducted with a nuclear <br /> density gauge to ensure 90% relative compaction and moisture content within ±4% <br /> of optimum moisture content (ASTM D 1557). Test and sample locations for the <br /> foundation layer soils are included in Appendix C. <br /> Vector's CQA Monitor obtained samples of the material for CQA testing ecto Q p Q g to ensure <br /> the material met the project specifications. Approximately 35,000 cy of subgrade <br /> fill was placed. The CQA monitoring of the subgrade fill placement included the <br /> following: <br /> Atterberg Limits and Grain Size Analysis of Subgrade Fill Soils: The CQA testing <br /> for the subgrade fill consisted of performing testing for Atterberg limit (ASTM D- <br /> 4318) and sieve analysis (ASTM D-422) at a frequency of one per 5,000 cubic yards <br /> (cy). Seven (7) sieve analyses and Atterberg limit tests were performed. A <br /> summary of the test results is included in Table 3. Detailed results of the subgrade <br /> fill material testing are included in Appendix C. <br /> Modified Proctor (ASTM D-1557): Vector's CQA Monitor performed seven (7) <br /> moisture-density relationships (ASTM D-1557), which corresponds to a frequency of <br /> Vector Engineering, Inc. • 143E Spring Hill Drive•Grass Valley, CA 95945-(530)272-2448 <br /> -11- <br />