Laserfiche WebLink
as little agitation as possible to reduce potential loss of volatile constituents. Major ions, 7DS, <br /> and metals analyses (in non-preserved containers) will be collected next followed by samples to <br /> be collected in preserved containers. Containers will be filled directly from the disposable bailer, <br /> immediately capped, and placed in a <br /> temperature-monitored iced chest. Caution will be Used not <br /> to overfill bottles containing a pfeservative. Temperature will be monitored by placmg* a <br /> thermometer in the chest and checking to make sure that there is'sufficientin he <br /> IC.e chest to <br /> maintain a temperature of approximately 4 degrees Celsius. The 'lab-oratory will measure, <br /> document, and report the temperature of the sample container upon arrival at the laboratory.. <br /> The analytical laboratory places a total of 2 ml of nitric add-in some of the I liter bottles to <br /> reduce the pH to below. 2. On an annual basis an extra preserved bottle will be .filled with <br /> groundwater and-the pH measured in the bottle. It is'assumed that the PH will be-below 2; If it <br /> is not the field technician will add nitric acid in measured amounts until the pH is below 2. This <br /> added quantity of acid will be placed in all the preserved bottics.durin.9 the following m <br /> . onitoring <br /> rounds until it is checked again the following-y!:ar­-Sample:-pH--vvilI"- be-confirmed:at:the,_: <br /> laboratory and recorded- Deviations will be documented and reported by the laboratory_ <br /> Samples;to be submitted for metals analysis-will. be filtered in the field- Filtering-will be <br /> performed using an in Eric filter mechanism which uses the-pumping ' - c <br /> process-of. he dedicated <br /> pumpto draw water through the 4 micron filter-_ A new filter will be used at each well. The new , <br /> filters -will have a minimum of one filter volume of groundwater pressurized <br /> through them to- <br /> reduce adsorption effects. The actual filtered-sample.will not be collected.until a minimum of <br /> two filter volumes of groundwater has been passed through the filter. For wells without <br /> dedicated pumps, the samples are transferred from the bailer,through a filter apparatus,. into the <br /> appropriate sample container- The filter apparatus consists of a pressure vessel, a hand-operated. <br /> pressure pump, and a filter cartridge- Water from the bailer is placed in the pressure -vessel and <br /> enough air pressure(via the hand pump)is applied to force water through the Meer cartridge into <br /> the sample bottles. The pressure vessel is washed in Alconox, steam cleaned, and rinsed with <br /> deicnized water between wells. A new Mter cartridge is used at each well. <br /> Simples will be labeled with a unique sample identification number, project identification <br /> number, sample location, and date and time sampled. Samples will be transported to the contract <br /> Laboratory under strict chain-of-custody procedures- <br /> ' 023483 949-FO I W I OR325 A-9 July 14,2004 <br /> CMY4�ht 2000 KkWcldcr,la,_ <br />