Northern Portion of WMU FU-06 August 2006 <br /> Forward Landfill Prolect No.021605.07 <br /> The holes in the geomembrane resulting from destructive seam sampling were <br /> covered by GSE immediately after sampling. The repair was completed by placing <br /> an extrusion welded patch of the same material. The continuity of the new seams <br /> in the repaired area was tested with the same procedure as described in the vacuum <br /> box testing procedures discussed previously. <br /> Size of Samples - Prior to testing in the laboratory, two samples, one at each end of <br /> the actual sample location, were cut for field-testing. If both specimens passed the <br /> field test, the sample was taken to the laboratory for testing. The size of the <br /> destructive samples was approximately 12 inches wide by 42 inches long. <br /> Laboratory Testing - The samples were taken to Vector's on-site laboratory for <br /> destructive testing of the seam. The samples were tested with a certified, <br /> calibrated tensiometer according to the requirements of ASTM D-6392. After seam <br /> strength tests for the destructive samples were obtained, the results were given <br /> verbally to the Contractor and were also reviewed by Vector's CQA Officer. The <br /> results of the destructive seam tests are presented within Appendix C. <br /> 4.2.4 Defects and Repair <br /> Vector's CQA Monitor checked seams and non-seam areas of the geomembrane for <br /> defects, holes, blisters, undispersed raw materials, and for signs of contamination <br /> by foreign matter. Vector's CQA Monitor examined each suspect location. Vector's <br /> CQA Monitor distinctively marked the repair area with a description of the required <br /> type of repair. No materials were placed over the geomembrane until Vector's CQA <br /> Monitor had approved the repair. <br /> The repairs were conducted in accordance with the applicable method specified <br /> within the project specifications. Vector's CQA Monitor reviewed each repair and <br /> Vector Engineering,Inc.•143E Spring Hill Drive•Grass Valley, CA 95945•(530)272-2448 <br /> -11- <br />