Laserfiche WebLink
Sampling Equipment <br /> Interim gas sampling probes were used to monitor sabs'tnrfaceries at the landfill <br /> g perimeter. <br /> Each Proms consists of a 5-foot long, YAnch diameter stainless steelP'i , <br /> pe, with Y4 inch holes <br /> staggexed every 2 inches at the bottom 1 g niches to allow for gases to migrate into the probes, q <br /> pointed tip was welded to the end of the probe for better penetration. <br /> A ball valve and brass fitting were instaed at the top of each probe to contain gas pressures and <br /> facilitate instrument hook-up to the probe. The valves were lett closed etc t during monitoring <br /> or instrument reading- Each probe is tagged with-a brass plate and id <br /> "GP-10". entified as "GP-1" through <br /> AGA-90 Landtec Infra-red-Gas Analyzer was used to monitor methane, carbon.dioxide.(Co-,), <br /> and oxygen (OD levels at each probe location. The analyzer was calibrated for methane, COz,and <br /> 02 prior to use in the field_Calibration.logs are.included.in this report, <br /> Gas Monitoring <br /> a <br /> Ambient air measurements of methane, oxygen, carbon dioxide; and bammeWc•pressure•wem } <br /> taken at each gas probe location_ Those readings were recorded and-the fiLstrument, was <br /> connected to the probe- The valve was opened and probe.gas pressure moments were taken. <br /> The probe was then. purged fortwo. probe volumes. gs-were then Bollat <br /> ajjpro)iy 3.0- to60-second in ,•until__a stable reading was .obtained.: These <br /> measurements of methane, oxygen, carbon dioxide, and ambient barometric pressure wire then <br /> marded. Monitoring was also conducted at various locations in dure 'building sites for the <br /> presence of methane,gas. Monitoring was conducted at the office trailer at the entrance to the <br /> 12ndf 11, trailer boxes- at the service shop, and trailer boxes at the transfer building. These <br /> locations were monitored for any gas packeu at the foundation and nearany opening from the <br /> floor such as piping holes,electrical conduits,or.floor cracks. <br /> LYSIMETERS <br /> Lysimetcrs were sampled using the following standard protocol: <br /> 1- Prior to sampling lysimeters,the pressure-vacuum equipment is checked.'and cleaned. I <br /> E41-F01\23IOR3Z A•12 J*14,2000 <br /> 2Q00 .1pc. <br />