My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2006_7
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2006_7
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 11:44:01 PM
Creation date
7/3/2020 10:52:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2006_7
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2006_7.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WASTE DISCHARGE REQUIREMENTS ORDER NO RS-2003-0049 <br /> FORWARD INC.AND ALJ-.[ED WASTE INDU.STPMS -17- <br /> FOR OPERATION OF <br /> FORWARD CLASS ff LANDFILL <br /> SAN JOAQUIN COUNTY <br /> D. CONST RUCTION SPECTRCATIONS <br /> L The Discharger shall submit for Executive Officer review and approval prior to <br /> construction, design plans and speei£tcations for new Tlnits and expansions of existing <br /> Units, that include the following_ <br /> a. A Construction Quality Assurance plan meeting the requirements of§20324 of Title <br /> 27; and <br /> b. A geotechnical evaluation Of the soils proposed for use in construction of the low <br /> hydraulic conductivity layer; and <br /> c. An unsaturated zone monitoring system, consisting of a pan lysimeter shall be <br /> installed beneath the unit leachate sump. <br /> 2. The bottom liner of all new Units and lateral expansion areas of existing Units shall be <br /> constructed in accordance with the following composite liner designs: a prepared <br /> subgrade; a 24-inch thick, low-petn-ieability soil layer(111iniartum permeability of 1 X 10"1 <br /> cm/sec); a 60-n-111 .high density polyethylene (.HDPE)geomembrane; a 12-ounce/square <br /> yard cushion geotexti le (may be omitted if the LCRS gravel is sub-angular to rounded); a <br /> 12-inch LCR.S gravel drainage layer; an 8-ounce/square yard separator geotextile; and a <br /> 12-inch thick protective cover soil operations layer. The side slope liner of all new Units <br /> and later expansion areas of existing Units shall be constructed in accordance with the <br /> following composite liner design: a prepared subgrade; a GCL or a 24-inch thick low <br /> permeability soil layer (minimum permeability of the soil l X 1,0-7 cm//sec); a <br /> geoeornposite drainage net; and a 12-inch thick protective cover soil operations layer. <br /> 3. The Discharger may propose changes to the liner systern design prior to construction, <br /> provided that approved components are not eliminated, the engineering properties of the' <br /> components are not substantially reduced, and the proposed liner system results in the <br /> protection of water, quality equal to or greater than the design prescribed by.Title 27 and <br /> this Order. The proposed changes may be made following approval by the;Executive <br /> Officer. Substantive changes to the design require reevaluation as an engineered <br /> alternative and approval by the Board. <br /> 4. If the Discharger proposes to construct a liner system in which a GCL is placed on top of <br /> a subgrade, the subgrade for the bottom and the side slopes of the Unit shall be prepared <br /> in an appropriate manner using accepted engineering and construction methods so as to <br /> provide a smoot:h surface that is free from rocks, sticks, or other debris that could damage <br /> or otherwise limit die performance of the GCL. <br /> 6l d 012090£££9 'ON/99:E l 'iSM: t l 9002 0 l l0 NNOW) Nodi <br />
The URL can be used to link to this page
Your browser does not support the video tag.