My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2007_1
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2007_1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:28 PM
Creation date
7/3/2020 10:52:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2007_1
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2007_1.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Global Presence <br /> Personal Attention <br /> HERST & ASSOCIATES, INC <br /> �r J <br /> 1;a L` j11'J l <br /> ' Mr.Rick Jaime � !; <br /> California Department of Corrections and Rehabilitation <br /> 7650 S.Newcastle Road/P.O.Box 213004 01—'T I 1 20017 <br /> ' Stockton,CA 95213-9004 <br /> f�j ryry L <br /> October 8,2007 J <br /> tDear Mr.Jaime: <br /> Summary of Northern California Youth Center Sampling Results <br /> tSeptember 2007 <br /> On September 11, 2007, sampling was performed at the Northern California Youth Center(NCYC)to <br /> ' provide supplemental information regarding volatile organic compound(VOC) concentrations at Well <br /> #2, Well #4, and the indoor faucet location included in other recent sampling events. Sampling was <br /> performed by Herst&Associates,Inc. VOC analyses were performed by BC Laboratories,Inc. <br /> ' Based on the sample results, there were no MCL exceedances at the indoor faucet location during <br /> September 2007. A summary of detected VOCs is provided in the attached table. <br /> Well #2 (reported to be a supplemental water supply well that operates about 20% of the year during <br /> peak demand periods) continued to exhibit a tetrachloroethene concentration slightly above the MCL. <br /> The September 2007 tetrachloroethene concentration at Well #2 was reported at 6.8 ug/l compared to <br /> ' an MCL of 5 ug/l. <br /> Well #4 (reported to be the primary water supply well for the facility) yielded a tetrachloroethene <br /> ' concentration well below the MCL. The September 2007 tetrachloroethene concentration at Well #4 <br /> was reported at 1.4 ug/1. <br /> ' Quality assurance samples collected during the September 2007 sampling event included a field blank <br /> at Well #2, a field blank at the indoor faucet, a trip blank, and duplicate samples at Well #4 and the <br /> indoor faucet. The field blank sample at Well #2 was collected to provide an indication of VOCs <br /> ' present in the ambient outdoor air or the laboratory analytical process. The field blank sample at the <br /> indoor faucet location was collected to provide an indication of VOCs present in the ambient indoor air <br /> or the laboratory analytical process. The trip blank sample was collected to provide an indication of <br /> ' any VOCs associated with shipment or the laboratory analytical process. The duplicate samples were <br /> collected to provide an indication of sampling and laboratory testing reproducibility. <br /> The September 2007 field blank samples yielded no detectable concentrations of VOCs except for <br /> ' chloroform in the field blank sample collected at the indoor faucet. Water at the indoor faucet has been <br /> chlorinated. Chloroform is a common by-product of the chlorinated water. Chloroform was not <br /> detected in the samples collected from Well#2,Well#4,or the indoor faucet. All VOCs were reported <br /> ' as non-detect in the trip blank sample. Duplicate sample results for the September sampling event were <br /> similar to the original sample results,indicating good reproducibility. <br /> ' 4630 South Highway 94—North Outer Road Telephone(636)939-9111 <br /> St.Charles,Missouri 63304 Fax(636)939-9757 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.