My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2007_12
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2007_12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:25 PM
Creation date
7/3/2020 10:52:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2007_12
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2007_12.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
First Quarter 2007 Groundwater Treatment <br /> Facility Monitoring Report <br /> Forward Landfill WDR Order No. R5-2003-0080 <br /> 1.0 Summary <br /> This First Quarter 2007 Monitoring Report for the Forward Incorporated (Forward) Landfill <br /> Groundwater Treatment Facility (GTF)presents the monitoring results for influent and <br /> effluent.This report was prepared as stipulated by the Central Valley Regional Water <br /> Quality Control Board (CV Water Board) Waste Discharge Requirements (WDR) Order <br /> No. R5-2003-0080,which was adopted on April 25, 2001 <br /> Following review of the information presented in this document,the following conclusions <br /> have been made: <br /> ® The GTF operated for 2,189 hours between December 27,2006,and March 31,2007,at <br /> 96.4 percent uptime, and treated 25.378 million gallons of groundwater. During this <br /> period, the GTF removed approximately 3.1 pounds of volatile organic compounds <br /> 1 (VOC). <br /> • During first quarter 2007, effluent samples collected in January,February,and March <br /> met WDR Order No. R5-2003-0080 for VOCs. No VOCs were detected. <br /> • An apparent leak in the buried groundwater conveyance pipeline was repaired on <br /> January 9,2007. The leak was located approximately 400 to 450 feet east of Extraction <br /> Well (EW)-2. EW-2 was restarted on January 11,2007. <br /> • A leak occurred inside the pipe vault adjacent to EW-2 on March 21,2007.EW-2 was <br /> turned off and the pipeline between EW-1 and EW-2 was isolated on March 21,2007,to <br /> prevent further leaks.The leak was caused by a cracked check valve inside the vault. <br /> Repairs to the piping inside the vault are scheduled for the week of April 2,2007. <br /> 2.0 Operational Summary <br /> The GTF operated for 2,189 hours between December 27, 2006,and March 31, 2007, at <br /> 96.4 percent uptime, and treated 25.378 million gallons of groundwater at an average flow <br /> rate of 193 gallons per minute, or 0.278 million gallon per day. During this period,the GTF <br /> removed approximately 3.1 pounds of VOCs. Table 1 presents the monthly average effluent <br /> flow rates in gallons per day. <br /> i <br /> RDDl071060007(NLH3445.DOC) i <br />