Laserfiche WebLink
To check for leakage below the liner, vadose zone monitoring is required by the <br /> RWQCB. The vadose zone will be monitored using porous suction cup or pan <br /> lysimeters that have been, or will be, installed concurrently with the construction <br /> of the LCRS' in the WMUs. These lysimeters are located beneath each sump to <br /> evaluate the effectiveness of the LCRS'. <br /> 3.11 SITE SECURITY <br /> The Forward Landfill is currently equipped with a perimeter fence, gates, locks <br /> and signs. The fencing and locked gates restrict access by persons and vehicles <br /> other than those authorized. Components of the monitoring, control, and <br /> recovery systems at the site will be protected from unauthorized access in <br /> accordance with the approved final closure and post-closure maintenance plans. <br /> A sign will be posted in a visible location at the main point of access to the <br /> facility within 10 days of receiving the final shipment of waste. The sign will <br /> indicate where the closure and post-closure maintenance plans will be kept and <br /> where they can be viewed by the public. The sign will also clearly indicate a <br /> telephone number for emergency notification. Proper maintenance of the sign <br /> will ensure legibility and upright conditions for the duration of the post-closure <br /> period. These signs will be written in English and will be clearly visible during <br /> daylight hours at 25 feet from the site boundary to persons with normal vision. <br /> 3.12 REMOVAL OF EXISTING STRUCTURES <br /> Forward will provide for the security, monitoring, and maintenance of all onsite <br /> structures during the closure and post-closure period, in accordance with the <br /> approved final post-closure maintenance plan. Onsite structures not essential to <br /> environmental monitoring during the post-closure maintenance period or other <br /> solid waste management operations at the site will be removed during closure <br /> construction in accordance with the applicable regulations. For the Forward <br /> Landfill, these structures include the scales and scalehouse. <br /> Structures currently existing on the Forward Landfill are the transfer station and <br /> office trailers and maintenance buildings. The transfer station will be removed, <br /> ® prior to closure, as part of ongoing operations during the time refuse is being <br /> placed in the area south of the South Branch. The office trailers and <br /> Forward Landfill PCPCMP 3-14 <br /> L:\Allied\2000.193\Reports\FinaiPCPCMP:FL-sec3.doc:5/21/02 BRYAN A.STIRRAT&ASSOCIATES <br />