Laserfiche WebLink
MD - MACHINE DIRECTION <br />TO - TRANSVERSE DIRECTION <br />DC#1991 Record#272 PPrecision Geosynthetic Laboratories <br />TABLE 1. <br />MATERIAL PROPERTIES <br />CLIENT:VECTOR ENGINEERING <br />PROJECT: Forward Landfill <br />Date Received: 8/1/2008 <br />QC'd By: <br />Date Reported: 8/5/2008 <br />PGL Job No.: <br />G080912 <br />Client Sample ID: R#94881.01 <br />PGL Control No.: <br />49113 <br />Material Description: 7 oz Non -woven Geotextile <br />SPECIMENS <br />Proi. <br />1 2 3 4 <br />6 6 7 <br />8 <br />9 <br />10 <br />Avg. <br />-9t-d.Dev. <br />wn <br />max <br />Specs. <br />METHOD <br />DESCRIPTION <br />ASTM D6261 <br />Mass per Unit Area (oz/ yd .2) <br />Test Specimen Size: 4"x 8" <br />8.2 8.6 8.3 8.4 <br />8.2 <br />8.3 <br />0.2 <br />8.2 <br />8.6 <br />>7 min <br />ASTM D4632 <br />Grab Tensile <br />Test was performed as directed in D4632, dry condition. Intron Tensile Testing Machine with hydraulic action grips and <br />I in x 2 in rubber faces was used. Maximum load used for testing., 1500 lbs <br />Grab Breaking Load (lbs) <br />MD 234 220 221 206 <br />230 226 226 <br />226 <br />227 <br />231 <br />226 <br />8 <br />206 <br />234 <br />>160 aVg <br />TD 202 230 221 211 <br />206 230 240 <br />226 <br />222 <br />226 <br />221 <br />12 <br />202 <br />24a <br />Apparent Breaking Elongation (percent) <br />MD 73 72 74 74 <br />73 77 76 <br />75 <br />76 <br />77 <br />75 <br />2 <br />72 <br />77 <br />TD 91 94 90 87 <br />93 87 86 <br />89 <br />89 <br />94 <br />90 <br />3 <br />86 <br />94 <br />MD - MACHINE DIRECTION <br />TO - TRANSVERSE DIRECTION <br />DC#1991 Record#272 PPrecision Geosynthetic Laboratories <br />