Laserfiche WebLink
TABLE 2. <br />MATERIAL PROPERTIES <br />CLIENT:VECTOR ENGINEERING <br />PROJECT: Forward Landfill <br />Date Received: 8/1/2008 <br />Date Reported: 8/6/2008 <br />Client Sample ID: R#94881.09 <br />Material Description: 7 oz Non -woven Geotextile <br />ASTM D5261 Mass per Unit Area (oz/ yd .2) <br />Test Specimen Size: 4"x 8" <br />8.3 8A 8.0 8.2 8.0 <br />ASTM D4632 Grab Tensile <br />Test was performed as directed in 04632 dry condition. Instron Tensile Testing Machine with hydraulic action grips and <br />I in x 2 in rubber faces was used Maximum load used for testing: 1500 lbs <br />Grab Breaking Load (lbs) <br />MD 230 220 226 222 220 212 220 222 206 232 <br />TD 220 221 220 230 221 220 221 230 231 215 <br />Apparent Breaking Elongation (percent) <br />MD 73 74 77 80 76 76 76 69 73 73 <br />TD so 87 86 89 86 87 88 87 89 89 <br />MD - MACHINE DIRECTION <br />TO - TRANSVERSE DIRECTION <br />DC#1991 Record#272 P Precision Geosynthetic Laboratories <br />QC'd By: *50 <br />PGL Job No.: G080912 <br />PGL Control No.: 49114 <br />AM <br />Std. Dev. <br />223 <br />! ax <br />Specs. <br />8.2 <br />0.2 <br />8.0 <br />8.4 <br />>7 min <br />221 <br />8 <br />223 <br />6 <br />75 <br />3 <br />88 <br />1 <br />206 232 >160 aVg <br />216 231 <br />69 80 <br />as 90 <br />