- K <br /> 1 <br /> meter to sound. This point is usually clearly visible on the probe. If it is not visible it should t <br /> .located by dipping the prone into a water container where the contact,can be clearly seen, then. . <br /> marked. The total-length of the water level meter should correspond with the length of the <br /> mea " g tape. In addition, the individual marks oa the cable should correspond with the <br /> correct footage. If the cable does not match the measuring t then the difference(if consistent) <br /> should be calculated. as a percentage, C.e.; 100 foot cable measures 102. feet 98�/®). All <br /> measurements with the cable should-then be multiplied by 0.98 to correct for the error. If the <br /> Individual footage marks are not placed corYeefly and are not consistent in their deviation, the <br /> instrament should be replaced. <br /> If the water level indicator is constructed of a cable then calibration will be peirforined once per <br /> year. If there is a disanpancy, the conversion factor will be marked directly on the instrument. <br /> Water level indicators constructed of to are more subject to stretching be' <br /> calibrated <br /> ,I ping and should be calibrated - <br /> every 6 month and marked with the appropriate conversion. <br /> Caliibrati®n data for each' entwill.bc.recorded-aaadkep a.binder•atth=offcefor-fmae_•: - <br /> reference. The most recent calibration results will also be recorded in the technicians field notes. <br /> There is no specific form for water level indicator calibration. <br /> nH Mctcr <br /> pH is_subject to significant variations due to temperature, buffering capacity of the water, and <br /> instrument drift.-For this reason pH metersmust be-caft1matedbefore and after sampling on each.. <br /> day and at least once more during the day. To calibrate a pH meter the iastruatent reading is - <br /> 4usted to read correctly for solutions with a standard pK <br /> Standard solutions arc mixed fresh, according to package i sanctiods„•for saarpling'event. <br /> 'Standard solutions or powd=for pH 4,7, and 10 are comm ' - y wmil-ble. Thcse standards <br /> •arc Pumbased and cd after shelf life has Shelf lives vary depending on the <br /> brand of standards used. If solution is used,the expiration date of the solution will <br /> be noted on the calibration log. <br /> Although different ds of pH meters Yrary, c dibration pro.cedurqs arc similar for all of them- <br /> A Seatiatized calibration p • follows: <br /> I. Turn on the iastrum=4 check the batwzy, and allow to warm up if accessary:. - <br /> 23493949•FO IMI OR32S A-2 htEy 14,200 <br /> 24Q4 ' .lac. <br />