Laserfiche WebLink
Leachate samples were collected on a monthly basis and analyzed in the field for pH, <br /> specific conductance, and temperature.. In addition,to monthly monitoring, leachate is <br /> sampled annually during the fourth quarter monitoring period for the parameters listed in <br /> Table 2-1. Results of monthly field monitoring measurements, and analytical results for <br /> the fourth quarter 2011 are presented in Table 2-6. As shown on Table 2-6, eight <br /> dissolved metal constituents were detected, and two VOCs were detected(with one <br /> measured above its PQL). No semi-volatile organic compounds (SVOCs), herbicides, or <br /> pesticides were detected in the annual leachate sample. The results of the annual leachate <br /> sample indicate that there were no new COCs detected above the PQL, and as a result, <br /> verification testing is not required. <br /> 2.1.7 Surface Water Monitoring <br /> Site run-on and run-off control facilities are designed to effectively channel surface water <br /> to site stormwater/sedimentation ponds. According to the Operations Manager, there <br /> were no discharges to surface water during the reporting quarter. During the fourth <br /> quarter 2011 monitoring period, both surface-water monitoring stations FS W-1 and <br /> FSW-2 were reported dry by Del-Tech on November 2, 2011. <br /> 2.2 SUMMARY <br /> Groundwater quality conditions beneath the Forward Unit during the fourth quarter 2011 <br /> monitoring period are generally similar to those observed in previous monitoring periods. <br /> During the fourth quarter 2011 monitoring period, DIPS was measured above its PQL in <br /> the sample collected from well MW-16. In addition, the following VOCs were measured <br /> at estimated trace concentrations, DIPE in the sample collected from well MW-2A; <br /> acetone and DCDFM in the sample collected from well MW-10; and 1,1-DCA, cis-1,2- <br /> DCE, DCDFM, PCE, TCE, and TCFM in the samples collected from well MW-14. CLs <br /> were exceeded for one or more constituents in wells MW-10, MW-15, MW-16, and MW- <br /> 22. Excluding non-impact constituents and VOCs, confirmation sampling will be <br /> performed in February 2012 during the first quarter 2012 monitoring event, and in March <br /> 2012. The results of the confirmation sampling will be provided under separate cover. <br /> The fourth quarter 2011 leachate monitoring results are generally similar to those <br /> observed historically. During the monitoring period, eight dissolved metal constituents <br /> were detected and two VOCs were detected (with one VOC measured above its PQL). <br /> No SVOCs, herbicides, or pesticides were detected in the annual leachate sample. The <br /> results from the annual leachate sample indicate that there were no new COCs detected. <br /> c:\zon-0050\Fn_aQILdoc 7 Geo-Logic Associates <br />