My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2011_25
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2011_25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2020 12:45:50 AM
Creation date
7/3/2020 10:56:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2011_25
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2011_25.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
410
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Austin Road Landfill Health&Safety Plan <br /> Austin Road Landfill,Stockton,California Page 7 <br /> oxygen sensor to conduct air monitoring during drilling activities. Background levels must be <br /> established well upwind of the drilling locations. <br /> Prior to initiation of drilling, all utilities will be clearly staked by utility representatives. During drilling, <br /> workers will be aware of the location of overhead lines as well as any changes in drilling that might <br /> indicate the presence of a buried utility line. If it is believed that a utility line has been drilled into,drilling <br /> should immediately cease and the Project Health and Safety Officer will be notified. <br /> The following paragraphs describe air monitoring for combustible gases. Action level information is <br /> summarized in Table 3.1. <br /> Table 3.1 Air monitoring action levels <br /> Instrument Parameter Action level S 'is Resp2nse <br /> Above background in <br /> breathing zone for more than 5 <br /> minutes OR>5 ppm in Ventilate and increase <br /> breathing zone(other than a monitoring <br /> Photoionization Volatile Organic peak)OR>10 but<100 ppm <br /> Detector(PID) Compounds peak. <br /> (VOCs) >10 but<100 ppm in breathing <br /> zone for more than 5 minutes Temporarily cease <br /> OR>25 ppm in breathing zone operations <br /> (other than a peak)OR>50 <br /> but<100 ppm peak <br /> <19.5% in breathing zone at Ventilate and increase <br /> Combustible Oxygen o valleymonitoring <br /> Gas Indicator <19.5%in breathing zone Temporarily cease <br /> other than a valley operations <br /> 10%LEL in breathing zone Increased monitoring <br /> Combustible 25%LEL at depth <br /> gas indicator Methane gas 25%LEL 1 foot above hole or <br /> (CGI) casing,or 25%LEL in work Temporarily cease <br /> zone operations <br /> If the exact nature of the volatile contaminant(s) is unknown, any consistent readings in the breathing <br /> zone that are perceptibly above the upwind background level for more than 5 minutes, any readings in <br /> the breathing zone greater than 5 ppm other than a momentary peak, or any peak reading greater than <br /> 10 ppm but less than 100 ppm shall be the action level to ventilate the area and increase the <br /> monitoring frequency. <br /> Any reading consistently greater than 10 ppm above background (but less than 100 ppm) for 5 <br /> minutes, greater than 25 ppm other than for a brief peak, or any peak reading greater than 50 ppm but <br /> less than 100 ppm in the breathing zone will be the action level for temporarily ceasing operations. <br /> Any readings of oxygen concentration less than 19.5% during momentary valley shall be the action <br /> level to ventilate the area and increase the monitoring frequency. Readings of less than 19.5%oxygen <br /> for any duration longer than a momentary valley will be the action level for temporarily ceasing <br /> operations. <br /> Methane gas generated by the decomposition of organic matter is commonly associated with invasive <br /> work on and near sanitary landfills. Combustible gas monitoring will be performed when drilling all <br /> boreholes. <br />
The URL can be used to link to this page
Your browser does not support the video tag.