My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2011_26
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2011_26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 8:17:55 PM
Creation date
7/3/2020 10:56:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2011_26
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2011_26.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
159
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•'Generato 'circuit breaker OPEN <br /> Fault indications for: ' <br /> • Generator circuit breaker return signal fault <br /> • Generator circuit breaker closing fault <br /> • Generator circuit breaker opening fault <br /> Remote signals <br /> (Volt free contacts) <br /> • Generator circuit breaker CLOSED 1 NO <br /> The following reference and status signals must be provided by the switchgear supplier: <br /> Generator circuit breaker CLOSED 1 NO <br /> Generator circuit breaker OPEN 1 NO <br /> Generator circuit breaker READY TO CLOSE 1 NO <br /> Mains circuit breaker CLOSED 1 NO <br /> Mains circuit breaker OPEN 1 NO <br /> • Mains voltage 3 x 480/277 V or 3x 110V/v3—other measurement voltages available on request <br /> • Bus bar voltage 3 x 480/277 V or 3x 110V/v3—other measurement voltages available on request <br /> • Generator voltage 3 x 4.16 kV or 3x 110V/v3—other measurement voltages available on request <br /> Voltage transformers in star point with minimum 50VA, Class 1 <br /> The following volt free interface-signals will be provided by GE Jenbacher to be incorporated in <br /> switchgear. <br /> • CLOSING/OPENING command for generator circuit breaker <br /> (permanent contact) 1 NO + 1 NC <br /> • Signal for circuit breaker undervoltage trip 1 NO <br /> 1.11.02 OPC Interface of visualisation DIANE WIN via ETHERNET - <br /> OPTIO <br /> OPC data interface of GE JENBACHER visualization system DIANE WIN for the on-site process control via <br /> ETHERNET 100BASE-TX(IEEE 802.3u)and TCP/IP protocol. <br /> Software interface: <br /> Supported OPC specification: OPC DA 1.0 and 2.0 for analogue and digital information <br /> OPC AE 1.0 for digital information <br /> Type of access: Reading only <br /> Refresh rate of data: 1000 ms for measured values, setpoints and counters <br /> 100 ms for messages <br /> OPC is based on Microsoft Distributed Component Object Model (DCOM). Therefore all limitations of DCOM <br /> are valid for this interface! <br /> Data provided: <br /> 19.04.20112 TS JGS616 E22 4160V April 19 2011 Ameresco Forward LFG-WES <br /> 24132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.