Laserfiche WebLink
1-1 <br /> 1.0 INTRODUCTION <br /> 1.1 Purpose and Plan Organization <br /> This Partial Final Closure/Post-Closure Maintenance Plan (PFCPCMP) for the Forward <br /> Landfill (FL) has been prepared to implement closure of the Stage 1B area at the site. <br /> Stage 1 of the FL was divided into two areas, Stage 1A and Stage 1B. In response to <br /> actions requested by the Regional Water Quality Control Board (RWQCB), Central Valley <br /> Region, Stage 1A was closed in 2006 in accordance with the approved Stage 1A PFCPCMP <br /> (dated June 2005, BAS & Associates). The closure of Stage 1A involved approximately 30 <br /> acres. Similar to Stage 1A, Stage 1B is proposing an alternative final cover design <br /> incorporating an evapotranspirative (ET) final cover consisting of select on-site soil <br /> materials. <br /> This PFCPCMP has been prepared on behalf of Forward Inc., the owner/operator of the <br /> landfill, by SWT Engineering, Inc. (SWT) for submittal to the California Department of <br /> Resources Recycling and Recovery (CalRecycle), the San Joaquin County Environmental <br /> Health Department (acting as the Local Enforcement Agency [LEA]), and the RWQCB. <br /> Stage 1B (approximately 20 acres) of closure is being implemented at the FL and will be <br /> performed in accordance with the applicable regulatory standards included in California <br /> Code of Regulations, Title 27 (27 CCR), Chapters 3 and 4 and 40 Code of Federal <br /> Regulations (CFR), Subpart F. <br /> The improvements and systems requiring installation/modification for Stage 1B of this <br /> 2011 Partial Final Closure project include the final grading, final cover system, drainage and <br /> erosion control systems, landfill gas monitoring/control system, leachate control system, <br /> and modification of environmental control systems (i.e., landfill gas monitoring/control <br /> system during final cover placement). A description of these closure improvements for <br /> closure construction of Stage 1B is presented in this 2011 PFCPCMP. <br /> This PFCPCMP is comprised of the following sections: Introduction (Section 1.0) and Existing <br /> Environmental Control and Monitoring Systems (Section 2.0) present information which is <br /> common to both the Closure Plan (Section 3.0) and Post-Closure Maintenance Plan (Section <br /> 4.0). The Post-Closure Emergency Response Plan and Closure/Post-Closure Maintenance <br /> Cost Estimates discussions are presented in Sections 5.0 and 6.0, respectively. <br /> Professional Certification of Accuracy (Section 7.0), Recordkeeping (Section 8.0), and <br /> References (Section 9.0) comprise the remaining sections of this document. <br /> 1.2 Setting <br /> 1.2.1 Location <br /> The FL is located at 9999 South Austin Road in Manteca, California 95536 at approximately <br /> Latitude 37052' 94" and Longitude 121052' 59". The site is located in Section 3 of <br /> Township 1S, Range 7E, Mount Diablo Baseline and Meridian (MDB&M) and Section 34 of <br /> Township 1N, Range 7E MDB&M. The landfill is comprised of eight parcels, which includes <br /> the following Assessor's Parcel Numbers (APN): 181-150-07, 181-150-08, 181-150-09, <br /> Forward Landfill Stage 113 Partial Final Closure/Post-Closure Maintenance Plan-June 2011 <br /> SWT Engineering <br /> z:\projects\allied waste\forward\11-1014 partial fnl clsr pin\partial final closure plan document\text\sec 1.doc <br />