• included in Appendix C. <br />• <br />Final Construction Quality Assurance Report — WMU FU -13 <br />Forward Landfill <br />TABLE 3 <br />SUBGRADE FILL LABORATORY TESTING SUMMARY <br />SAMPLE <br />SOIL <br />MODIFIED PROCTOR <br />ATTERBERG LIMIT <br />GRAIN SIZE <br />pcf max <br />OMC <br />LL <br />PL <br />PI <br />3" <br />NUMBER <br />DESCRIPTION <br />SPECIFICATIONS <br />100% passing <br />ButtB-051613-S1 <br />Lt Brown Sand <br />124.2 <br />10.7 <br />50 <br />21 <br />29 <br />100% <br />w/silty clay <br />Butt -051613-S1 <br />Lt Brown Sand <br />114.3 <br />16.2 <br />51 <br />22 <br />30 <br />100% <br />w/silty clay <br />Butt -051613-S2 <br />Lt Brown Silty Clay <br />115.6 <br />17.1 <br />35 <br />18 <br />17 <br />100% <br />Butt -052113-S1 <br />Lt Brown Silty Clay <br />111.2 <br />17.6 <br />NP <br />NP <br />NP <br />100% <br />Butt -052113-S2 <br />Lt Brown Silty Clay <br />117.0 <br />16.3 <br />56 <br />21 <br />36 <br />100% <br />FLCB-0516-S1 <br />Brown Lean <br />117.5 <br />13.6 <br />26 <br />16 <br />10 <br />100% <br />ClaySandy <br />FLCB-0516-S2 <br />Brown Lean <br />124.9 <br />10.4 <br />29 <br />14 <br />15 <br />100% <br />Candy <br />FLCB-0516-S3 <br />Brown Sandy Lean <br />_ <br />- <br />36 <br />17 <br />19 <br />100% <br />Clay <br />FLCB-0516-S4 <br />Brown Lean <br />123.4 <br />11.0 <br />28 <br />15 <br />13 <br />100% <br />ClaySandy <br />FLCB-0516-S5 <br />Brown Lean Clay <br />123.3 <br />11.3 <br />29 <br />15 <br />14 <br />100% <br />w/ Sand <br />FLCB-0516-S6 <br />Brown Sandy Lean <br />119.9 <br />12.8 <br />28 <br />16 <br />12 <br />100% <br />Clay <br />Moisture and Density Testing: GLA's CQA Monitor recorded 157 passing in-place nuclear <br />method unit weight (ASTM D-2922) and moisture content (ASTM D-3017) tests during the <br />compaction of the subgrade/buttress fill soil materials. The total number of passing tests <br />recorded corresponds to a frequency of 1 test per 318 cy, which satisfies the specified <br />minimum required frequency of 1 test per 500 cy. Also, 11 subgrade/buttress fill soil samples <br />were collected at the nuclear test locations for microwave and oven moisture content <br />determination, to check the accuracy of the nuclear gauge. The specified frequency for this test <br />was 1 per 45,400 cy; the actual frequency was 1 test for every 5,000 cy. Summaries of the field <br />moisture -density tests can be found in Appendix C. <br />• Upon completion of the subgrade/buttress fill soil placement on the slopes, the Contractor <br />11 Geo -Logic <br />ASSOCIATES <br />