Laserfiche WebLink
Water Quality Monitoring Report <br />Forward Landfill <br />is Non -Statistical Data Analysis <br />The non -statistical VOCwater analyses performed on the DMP well data indicates that <br />there were no VOCs detected in DMP wells for the Austin Unit, and as a result, no non - <br />statistical exceedances. <br />Concentration Limit Thresholds <br />In accordance with RWQCB Order No. 115-2014-0006, the routine inorganic monitoring <br />data obtained for the Austin Unit during the first quarter 2014 monitoring period were <br />compared to intrawell concentration limits (CLs) established for each well. Since the <br />new WDR requires annual updates to the CLs and CL have not been updated since 2011, <br />inorganic CLs for the Austin Unit wells were recalculated and are presented in Table 3-3. <br />Details on the CL update are presented in Appendix D. As summarized in Table 3-3, only <br />the calcium concentration measured in well AMW-7 exceeded it CL during the first <br />quarter 2014 monitoring period. However, trend analysis indicates that there was not a <br />statistically significant increasing temporal trend for calcium concentrations measured <br />in well AMW-7. Trend analysis calculations are included in Appendix D. Since a VOC <br />release has already been acknowledged for the Austin Unit of the Forward Landfill <br />confirmation sampling is not required for the inorganic CL exceedance at well AMW-7. <br />• Further monitoring is necessary to evaluate if well AMW-7 should be grouped with the <br />corrective action wells. <br />3.1.5 Corrective Action/Evaluation Program <br />Field and laboratory results for CAP and EMP wells for the first quarter 2014 monitoring <br />period are summarized in Table 3-2. As shown in Table 3-2, 11 CAP/EMP wells reported <br />one or more VOCs exceeding a Practical Quantitation Limit (PQL), with CAP well AMW-1 <br />having the greatest number of VOCs (11) including seven measured above a PQL. An <br />annual report discussing the CAP and EMP monitoring results for the Austin Unit was <br />prepared by Herst & Associates (Herst, 2013) and reported under separate cover. <br />3.1.6 Cannery Waste Land Application Monitoring <br />Field and laboratory results for CWLAM wells for the first quarter 2014 monitoring <br />period are summarized in Table 3-4. Of note, water quality standards for the CWLAM <br />program have not been established yet and will be submitted with the Cannery Waste <br />Water Quality Protection Standards Report, due September 1, 2014. <br />3.1.7 Domestic Well Monitoring <br />• Two domestic wells (7898-A and 8106-A) were sampled on February 12, 2014. Table 3-5 <br />summarizes the current analytical results for the domestic well samples collected. PCE <br />M:\ 2014.0012\FA_1Q14.docx 11 <br />4/28/2014, Rev. 0 <br />