Laserfiche WebLink
5-5 <br />10 5.2.4 Final Cover <br />5.2.4.1 Regulatory Design Standards <br />California Final Cover Prescriptive Design Standard <br />The minimum final cover standards for Class II landfills contained in 27 CCR, Section 21090 <br />include: <br />♦ Foundation Layer: A minimum two -foot thick layer of soil placed immediately over <br />the entire surface of the last lift of refuse. This layer shall have the appropriate <br />engineering properties, so as to provide a relatively unyielding surface upon which to <br />place and compact the low -hydraulic -conductivity layer. <br />♦ Low -Hydraulic -Conductivity Layer: A minimum one -foot thick layer of clean low - <br />hydraulic -conductivity soil containing no waste or leachate placed over the <br />foundation layer. The low -hydraulic -conductivity (or low through -flow rate) soils shall <br />be placed on top of the foundation layer and compacted to attain a hydraulic <br />conductivity, which is the lesser of either; <br />-1 x 10-6 cm/sec. <br />-The hydraulic conductivity of any bottom liner system or underlying natural geologic <br />materials. <br />♦ Erosion Resistant Layer: A minimum one -foot thick layer of soil containing no waste <br />or leachate placed on top of all portions of the low -hydraulic conductivity layer. <br />Vegetation root depths must not exceed the topsoil layer thickness. Vegetation is to <br />be replanted, as needed, to provide effective erosion resistance. <br />The final cover should be designed to allow for minimal maintenance. The final grading <br />design for areas flatter than 5:1 (horizontal:vertical) will have a gradient of at least 3%, to <br />prevent surficial slumping which may cause ponding and accommodate differential <br />settlement during the post -closure maintenance period. <br />Federal Final Cover Prescriptive Design Standard <br />The minimum final cover standards, as outlined in the closure criteria of 40 CFR, Subpart F, <br />Section 258.60, include: <br />♦ A cover with a permeability less than or equal to the hydraulic -conductivity of any <br />bottom liner system or natural sub -soils present, or a permeability no greater than 1 x <br />10-5 cm/sec, whichever is less. The barrier layer shall consist of a minimum 18 <br />inches of earthen material. <br />♦ A cover which minimizes erosion of the final cover by the use of an erosion resistant <br />layer that contains a minimum six inches of earthen material and is capable of <br />sustaining native plant growth. <br />Forward Landfill SWT Engineering <br />Joint Technical Document - April 2014 <br />z:\projects\allied waste\forward\five year permit rvw 2013\jtd-5 yr pr 2013\text\sec 5—final.doc <br />