My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2014_8
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2014_8
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2020 12:38:44 PM
Creation date
7/3/2020 10:58:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2014_8
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2014_8.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
595
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WASTE DISCHARGE REQUIREMENTS ORDER NO. R5-2014-0006 -16- <br /> FORWARD INC.AND REPUBLIC SERVICES INC. <br /> FORWARD CLASS II LANDFILL <br /> SAN JOAQUIN COUNTY <br /> 25 September 2002 the discharger submitted a revised performance demonstration and on <br /> 24 October 2002 staff responded indicating concurrence with the revised demonstration. <br /> The proposed liner system consists of a single composite base liner from bottom to top <br /> composed of: a prepared subgrade, two feet of compacted clay, 60-mil HDPE, one-foot <br /> gravel drainage layer, filter fabric, one-foot operations layer, and a first waste layer <br /> composed of selected waste. Side-slope liners to be composed of: a prepared subgrade, <br /> two-feet of compacted clay or GCL, 60-mil HDPE, geocomposite drainage net, and one-foot <br /> operations layer. Forward will install a double composite liner under landfill sumps, conduct <br /> an electric leak test over the sump, conduct CQA inspections during placement of the <br /> operations layer and first lift of refuse, conduct an electric leak test over the entire base liner <br /> after installation of the operations layer; and use selected material in the operations layer. <br /> The report demonstrated that the proposed liner system would effectively prevent the <br /> migration of wastes from the unit. <br /> CONSTRUCTION AND ENGINEERED ALTERNATIVE <br /> 63.On 17 June 1993, the State Water Board adopted Resolution 93-62 implementing a State <br /> Policy for the construction, monitoring, and operation of municipal solid waste landfills that is <br /> consistent with the federal municipal solid waste regulations promulgated under 40 Code of <br /> Federal Regulations section 258 (a.k.a., Subtitle D). Resolution 93-62 requires the <br /> construction of a specified composite liner system at new municipal solid waste landfills, or <br /> expansion areas of existing municipal solid waste landfills, that receive wastes after 9 <br /> October 1993. Resolution 93-62 also allows the Central Valley Water Board to consider the <br /> approval of engineered alternatives to the prescriptive standard. Section III.A.b. of <br /> Resolution 93-62 requires that the engineered alternative liner systems be of a composite <br /> design similar to the prescriptive standard. <br /> 64.Title 27, section 20080(b) allows the Central Valley Water Board to consider the approval of <br /> an engineered alternative to the prescriptive standard. In order to approve an engineered <br /> alternative in accordance with Title 27, sections 20080(c)(1) and (2), the Discharger must <br /> demonstrate that the prescriptive design is unreasonably and unnecessarily burdensome and <br /> will cost substantially more than an alternative which will meet the criteria contained in Title <br /> 27, section 20080(b), or would be impractical and would not promote attainment of applicable <br /> performance standards. The Discharger must also demonstrate that the proposed <br /> engineered alternative liner system is consistent with the performance goal addressed by the <br /> particular prescriptive standard, and provides protection against water quality impairment <br /> equivalent to the prescriptive standard in accordance with Title 27, section 20080(b)(2). <br /> 65.Water Code section 13360(x)(1) allows the Central Valley Water Board to specify the design, <br /> type of construction, and/or particular manner in which compliance must be met in waste <br /> discharge requirements or orders for the discharge of waste at solid waste disposal facilities. <br /> 66.The Discharger proposes a liner system which will be designed, constructed, and operated in <br /> accordance with the criteria set forth in Title 27, and the provisions in State Water Board <br /> Resolution 93-62 for municipal solid wastes. <br />
The URL can be used to link to this page
Your browser does not support the video tag.