My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2015_2
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2015_2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2020 2:53:52 PM
Creation date
7/3/2020 10:59:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2015_2
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2015_2.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Water Quality Monitoring Report <br /> Forward Landfill <br /> ® Samples were collected by Del-Tech from each sample point containing sufficient liquid <br /> and submitted to BC Laboratories (BC) of Bakersfield, California, a state certified <br /> laboratory under contract to Forward. The third quarter 2015 samples were analyzed <br /> for the routine monitoring parameters stipulated in RWQCB Order No. 115-2014-0006. <br /> Table 2-1 summarizes site monitoring parameters, analytical methods, and monitoring <br /> frequency. Water quality samples were also analyzed in the field for oxygen reduction <br /> potential (ORP), turbidity, temperature, specific conductance, and pH and recorded on <br /> well data sheets. The groundwater monitoring wells and leachate monitoring points <br /> were sampled in accordance with the sampling and analysis plan detailed in Appendix E. <br /> The well data sheets, raw laboratory data, certificates of analyses, and chain-of-custody <br /> records related to the sampling program are included in Appendix F. Field and <br /> laboratory analyses are summarized in Tables 2-2 through 2-7 and cumulative tabulated <br /> data for all monitoring points and constituents for groundwater, unsaturated zone, <br /> leachate, and surface water are presented in Appendix F. <br /> 2.1.2 QA/QC Results <br /> The quality assurance/quality control (QA/QC) program completed for the third quarter <br /> 2015 water quality monitoring event included analyses of two trip blanks, one field <br /> blank, laboratory method blanks, and one duplicate sample (DW-9690). The method <br /> blanks were analyzed for all of the analytes included in the monitoring program. The <br /> results of the QA/QC program indicate that no VOCs were detected in the QA/QC <br /> blanks. Inorganic constituents including calcium, magnesium, and sodium were <br /> measured at trace concentrations in one or more of the method blanks analyzed with <br /> groundwater samples. However, at these very low concentrations, these constituents <br /> did not affect the interpretation of primary sample results. The results of the duplicate <br /> sample collected from well DW-9690 yielded good correlation with a relative percent <br /> difference (RPD) less than four percent. Review of the sampling dates and laboratory <br /> analytical certificates indicates that all laboratory analyses were completed within <br /> required holding times. Based on the results of the laboratory QA/QC analyses, it is <br /> concluded that the laboratory data generated for the third quarter 2015 monitoring <br /> period are acceptable and the water quality samples collected from the Forward Unit <br /> appear to be representative of water quality at the site. <br /> 2.1.3 Groundwater Elevations and Contours <br /> Prior to purging and sampling, each well was sounded for water depth using a weighted <br /> electronic sounder to an accuracy of 0.01 foot, and the static water level was recorded <br /> on a Well Data Sheet (Appendix F). The groundwater elevations were calculated for <br /> each well by subtracting the depth-to-water measurement from the top-of-casing <br /> reference elevation. The current groundwater elevation data for the Forward Unit is <br /> summarized in Table 2-3. <br /> M:\2015.0014\FA 3Q15.docx 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.