My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_1993
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
31130
>
4400 - Solid Waste Program
>
PR0440003
>
Archived Reports
>
ARCHIVED REPORTS_1993
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:10 PM
Creation date
7/3/2020 11:04:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
1993
RECORD_ID
PR0440003
PE
4434
FACILITY_ID
FA0003698
FACILITY_NAME
CORRAL HOLLOW LANDFILL
STREET_NUMBER
31130
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25303010
CURRENT_STATUS
01
SITE_LOCATION
31130 CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4434_PR0440003_31130 CORRAL HOLLOW_1993.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
445
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plastic bottles and caps used in sampling for metals shall be soaked overnight in a I percent <br /> nitric acid solution. The bottles and caps shall then be triple rinsed with deionized water, and <br /> air dried before being used at the site. All plastic bottles and caps shall be constructed of linear <br /> polyethylene or polypropylene. Plastic bottles and caps shall be used only once and discarded <br /> after analysis is complete. <br /> Plastic bottles and caps used in sampling for general water-quality parameters are not routinely <br /> washed. They are used only once and discarded after analysis is complete. <br /> Before starting the sampling event, all equipment that will be used will be disassembled and <br /> cleaned thoroughly with a non-phosphate detergent(such as Alconox9)water, then steam cleaned <br /> with deionized water. Any parts that may absorb contaminants, such as plastic pump bladders, <br /> check vales, etc., shall be cleaned as described above or replaced. The inside surfaces of <br /> positive displacement(bladder) pump tubing shall be cleaned by heating the tubing overnight at <br /> 120°C with a low-flow, inert air source. Once the bladder pump is cleaned and reassembled, <br /> a pump blank will be collected by pumping organic-free water through the bladder pump <br /> assembly. The pump effluent will be sampled and analyzed by EPA Method 8010/8020. The <br /> pump effluent analysis must be below the method reporting limit for each parameter before the <br /> pump is used at the site for sample collection. <br /> Surface Compost]Leachate Sampling <br /> If sufficient flow is observed, compost leachate samples shall be collected with a dipper, or <br /> bailer consistent with the procedures listed in Section 9 of Test Methods for Evaluating Solid <br /> Waste: Physical/ cal Methods (SW-846, 3rd edition, November 1986). If low-flow <br /> conditions are encountered, ether a disposable syringe or a stainless steel scoop will be used to <br /> collect samples. A disposable plastic syringe will be used for collecting samples without <br /> disturbing bottom sediment in very shallow water conditions. In low-flow conditions, the flat <br /> bottom of a stainless steel scoop will be pressed against the bank and the water will flow with <br /> minimum disturbance into the scoop. Compost leachate samples collected shall be transferred <br /> into the appropriate sample containers. Compost leachate samples shall be filtered as required. <br /> Grab Compost Leachate SampHng <br /> If compost leachate samples are required from the evaporation, grab samples will be collected <br /> using a stainless steel bomb sampler from the leachate outfall as appropriate. Leachate samples <br /> shall be filtered as required and transferred into the appropriate containers. <br /> I_WQnDCr0VAMPMC1-4.TCY D-2 Novemba 23,1993 <br />
The URL can be used to link to this page
Your browser does not support the video tag.